| Date |
Text |
| 2001-06-12 00:00:00 | IMPACT FEES MUST BE PAID TO PALM BEACH | | | COUNTY. CALL 233-5025 FOR MORE | | | INFORMATION. | | | | | | SHOW A DETAIL FOR THE B10 BEAM | | | CONNECTION TO THE C2 COLUMNS. | | | | | | SHOW A CONSTRUCTION DETAIL FOR THE METAL | | | STUD WALL DEPICTED IN SECTION S3/2. | | | INCLUDE FASTENERS AND SPACING AS WELL | | | AS WINDOW CONNECTION. | | | | | | NOTE THE ASSUMED SOIL BEARING VALUE. | | | | | | THE PAD FOOTING ON SHEET S1 GRID G4 IS | | | NOT LABELED. | | | | | | SECTION 1 S/3 SHOWS A 12" LONG ANGLE | | | SUPPORTING THE BAR JOIST WHICH WILL | | | CONFLICT THE NOTED 2' OC SPACING OF THE | | | ANCHOR BOLTS. | | | | | | S2 IN THE VICINITY OF GRID H & I 5 CALLS | | | OUT AN ANGLE 3/8" THICK 8" LONG AND | | | DOES NOT AGREE WITH S5 WHICH SHOWS A | | | 1/4" ANGLE APPARENTLY CONTINUOUS. | | | PLEASE CLARIFY. | | | | | | PLEASE PROVIDE A RECENT SURVEY.IF THE | | | PHASE I BUILDING IS ON THE SAME LOT SHOW | | | THE OPENINGS IN THE FACING WALL SO THAT | | | COMPLIANCE WITH SBC TABLE 600 MAY BE | | | DETERMINED. |
|