Plan Review Notes
Plan Review Notes For Permit 01040482
Permit Number 01040482
Review Stop P
Sequence Number 2
Notes
Date Text
2001-05-24 00:00:00REVIEW NOTES ....PASSED....
  
 ....PROVISO...
  
 1) GENERAL NOTES #15 COPIES OF ALL DOC-
 UMENTS TO FILED WITH THE DEPARTMENT OF
 CONSTRUCTION SERVICES. CHANGE "L" TO
 CITY OF WEST PALM BEACH. GNI 1 OF 1.
  
 2) TYPICAL WATER RISER DIAGRAM - MAXIMUM
 FIXTURES ON 1/2" COLD IS 2 FIXTURES.
 MODEL COUNTYWIDE AMENDMENTS TO SPC-94
 607.7
  
 3) AIRCHAMBERS TO COMPLY WITH SPC-94
 607.8.2 & 607.8.3
  
 4) PAGE P-4, P/T #1 ON FLOOR PLAN SHOWS
 2 SEPARATE RISERS, BUT P/T #2 ONLY SHOWS
 A SINGLE RISER. TWO RISERS ARE REQUIRED.
  
 5) FAIR HOUSING ACT 1996 AMENDED 1998
 REQUIREMENT 7B REQUIRES THAT SPEC.A OR
 B BE SHOWN ON PLAN.
  
 6) PAGE A8.1 BACKING AT TUB TO BE 1'-5"
 NOT 1'-2" AS SHOWN ON PLAN. FHA-96
 AMEND. - 98 REQUIREMENT 6.
  
 REVIEW BY KEN STEVENS (561) 659-8096
 EXT. 8389


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved