Plan Review Notes
Plan Review Notes For Permit 01040371
Permit Number 01040371
Review Stop B
Sequence Number 1
Notes
Date Text
2001-04-12 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01040371
 915 S DIXIE HWY
 SUNCOAST AUTOBUILDERS
 (727) 561-0764
  
 1)- SBC 1004.2.2. A MINIMUM OF (2)
 APPROVED EXITS ARE REQUIRED FOR A
 BUSINESS OCCUPANY,PLEASE INDICATE THE
 SECOND MEANS OF EGRESS.
  
 2)- THE SITE PLAN INDICATES THAT THERE
 IS AN ELEVATOR TO THE SECOND FLOOR.THE
 FL ACCESSIBILITY CODE 4.13.6. HAS MAN-
 EUVERING CLEARENCES AT DOORWAYS TO BE
 CONSIDERED. THE COMPUTER ROOM & ENCLOSED
 OFFICE DO NOT MEET THE REQUIREMENTS OF
 THIS CODE SECTION, A COPY OF THE CODE
 SECTION IS ATTACHED.
  
 3)- SBC 1016.2.1. EMERGENCY LIGHTING IS
 NOT INDICATED ON THE PLAN.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 EX 8412