Date Text
2001-05-01 00:00:00BUILDING PLAN REVIEW
 900 31ST ST
 O/B DANIEL & DEBRA NEGER
  
 1)- PLANS ARE TO BE DESIGNED TO THE
 STANDARD BUILDING CODE'S PERSCRIPTIVE
 CODE FOR HIGH WIND AREAS (110 MPH).
  
 2)- PLANS NEED TO DETAIL A MONOLITHIC
 SLAB OR STEM WALL CONSTRUCTION.
  
 3)- PLANS NEED TO INDICATE THE ANCHOR
 SYSTEM OF THE POST TO SLAB, DETAIL THE
 CONNECTION OF THE POST TO BEAM CONNEC-
 TION BEAM TO RAFTER CONNECTION, ALSO THE
 RAFTER ATTACHMENT TO THE HOUSE (NOT
 FACIA). SPACING OF MATERIALS,DIMENSION
 OF MATERIALS, STRAPS, BUCKETS, OR HANGER
 STYLE AND MANUFACTURE WITH MODEL NUMBER.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659- 8096 EX 8412