| Plan Review Notes For Permit 01040330 |
| Permit Number |
01040330 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-04-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01040330 | | | O/B JARVIS, JOHN | | | 213 SEVILLE | | | | | | 1)- ADMINISTRATIVE CODE 104.2.1.- | | | ALL INFORMATION, DRAWINGS, SPECIFICATION | | | AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME & SIGNATURE OF THE PERSON RESPON- | | | SIBLE FOR THE DESIGN. | | | | | | 2)- SSTD 10-97 101.1 THIS STRUCTURE IS | | | TO COMPLY WITH THE REQUIREMENTS FOR | | | WIND IN SBC CHAP. 16. THE PRESCRIPTIVE | | | METHOD IS TO BE USED. SHOW COMPLIANCE | | | WITH EYEBROW AND WINDOW REPAIR. | | | | | | 3)- GLAZED OPENINGS REQUIRE TESTING FOR | | | WIND, 1707.4 10 SEC LOAD EQUAL TO 1.5 | | | THE DESIGN PRESSURE, DADE COUNTY OR | | | SBCCI REPORT ACCEPTTED.DOORS & WINDOWS. | | | | | | 4)- DETAIL FRONT STAIRS, THE PLAN INDI- | | | CATES THE STRUCTURE TO BE WOOD FRAME, | | | SHOW THE AIR GAP BETWEEN THE CONCRETE | | | STOOP AND WALL LINE. SBC103.7STATE MEMO | | | #692. | | | | | | 5)- SBC 1503.4.1.2. ROOFING SYSTEMS ARE | | | TO PROVIDE PRODUCT TESTING FOR 110MPH | | | WIND ZONE, SBCCI REPORT OR DADE COUNTY. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412 |
|