| 2001-04-09 00:00:00 | CHECKLIST: |
| | 1-ONE AND TWO FAMILY DWELLINGS MAY NOT |
| | REQUIRE AN ARCHITECT OR ENGINEER |
| | PROVIDED THAT ENTIRE DWELLING CONFORMS |
| | TO A PRESCRIPTIVE STANDARD ADOPTED BY |
| | THE CITY: SSTD 10-97. THEREFORE, |
| | DESIGNER SHALL USE THIS BOOK TO |
| | DESIGN THE STRUCTURE. |
| | SECTION 104.2.3 OF CITY AMENDMENTS. |
| | 2-DESIGNER TO PROVIDE HIS/HER NAME AND |
| | SIGNATURE ON ALL DRAWINGS AS REQUIRED |
| | BY SECTION 104.2.1 OF CITY AMENDMENTS. |
| | 3-BRING DRAWINGS TO PALM BEACH COUNTY TO |
| | VERIFY IF NEED TO PAY IMPACT FEES. |
| | BRING COUNTY STAMPED DRAWINGS AND |
| | RECEIPT AS REQUIRED. |
| | 4-DOOR FROM GARAGE TO BEDROOM IS NOT |
| | ALLOWED. SECTION 411.2.8 SBC 1997. |
| | 5-CLEARLY SPECIFY WINDOW TYPES AND SIZES |
| | -SPECIFY DOOR SIZES. |
| | 6-PROVIDE PRODUCT APPROVAL FOR: |
| | -EXTERIOR DOORS AND WINDOWS. |
| | -GARAGE DOORS WITH SIZES AS SHOWN ON |
| | PLANS AND ELEVATIONS. |
| | -FLAT ROOF SYSTEM TO BE USED. |
| | 7-STORM PANELS: |
| | -PROVIDE PRODUCT APPROVAL. |
| | -PROVIDE KEY PLAN AND A COMPLETE |
| | INSTALLATION SCHEDULE AS PER CITY |
| | SAMPLE ATTACHED. |
| | -CLEARLY INDICATE ON STORM PANEL |
| | DRAWINGS THE SPECIFIC MOUNTING |
| | CONDITIONS, ANCHOR TYPE AND SPACING TO |
| | BE USED ACCORDING TO THE MEAN ROOF |
| | HEIGHT, DESIGN PRESSURES, PANEL SPAN, |
| | EDGE DISTANCE, CONNECTION TYPE AND |
| | STRUCTURE TO BE ATTACHED TO (CONCRETE |
| | BLOCK). |
| | 8-PROVIDE COMPLETE STRUCTURAL BUCK |
| | DETAILS FOR GARAGE DOORS, WINDOWS AND |
| | EXTERIOR DOORS. |
| | SECTION 104.2.2 OF CITY AMENDMENTS. |
| | 9-PROVIDE ENERGY CALCS. AS REQUIRED BY |
| | THE FLORIDA ENERGY CODE FOR BUILDING |
| | CONSTRUCTION, 1997 EDITION. |
| | 10-CLEARLY SPECIFY ON PLANS HOW THE |
| | OPENINGS FOR DOORS AND WINDOWS ARE |
| | REINFORCED. |
| | -SPECIFY HOW ARE BUILDING CORNERS |
| | REINFORCED. |
| | -PROVIDE BEAM AND LINTEL SCHEDULE. |
| | -CLARIFY IF ROOF IS GOING TO HAVE |
| | PARAPET WALLS OR NOT. AND HOW IS THE |
| | WATER GOING TO RUN OFF. |
| | 11-PROVIDE A COMPLETE HURRICANE ANCHOR |
| | SCHEDULE FOR ROOF FRAMING. AND SPECIFY |
| | UPLIFT LOADS AS CALCULATED ACCORDING |
| | TO THE PRESCRIPTIVE METHOD SSTD 10-97. |
| | 12-SPECIFY TYPE AND GRADE OF STRUCTURAL |
| | LUMBER TO BE USED. |
| | 13-SPECIFY HOW THE ROOF IS GOING TO BE |
| | VENTILATED AS REQUIRED BY SECTION |
| | 2309.7 OF SBC 1997. |
| | 14-SPECIFY SAFETY GLASS (TEMPERED GLASS) |
| | FOR WINDOWS WITHIN 24" RADIOUS OF |
| | SWING DOORS AS REQUIRED BY SECTION |
| | 2405.2 SBC 1997. |
| | 15-ROOF SHEATHING TO BE 19/32" MIN. NOT |
| | 1/2". ALSO, SPECIFY NAIL TYPE AND |
| | SPACING AS REQUIRED BY SECTION 2306 OF |
| | CITY AMENDMENTS TO SBC 1997. |
| | 16-FLAT ROOF TO HAVE A MINIMUM SLOPE OF |
| | 1/4" PER FT. SEC. 1503.1.2.3 SBC 1997. |
| | 17-TOILET ROOM TO HAVE WINDOW WITH MIN. |
| | 3 SQ. FT. OF OPEN AREA OR PROVIDE |
| | MECHANICAL VENTILATION AS REQUIRED BY |
| | SECTION 1203.4.2 OF SBC 1997. |
| | 18-FILE NOTICE OF COMENCEMENT. |
| | |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ AT 659-8096 EXT. 8232. |