Notes
Date Text
2001-03-29 00:00:00O/B SIMMONS, RONALD
 369 PALMETTO ST
 PERMIT # 01030543
  
 1)- SBC 104.2.2 ADDITIONAL INFORMATION
 : SURVEY REQUIRED (2 COPIES) A RECENT
 SURVEY WITH IN A YEAR OLD.
  
 2)- DISCREPANCY BETWEEN THE ENERGY SHEET
 ATTIC INSULATION R-30 VS. SHEET A2 R-19.
  
 3)- STATE MEMORANDUM 692; PRE CONSTRUC-
 TION SOIL TREATMENT FOR SOIL,SBC.103.7.-
 3.3.5 ADDITIONAL SOIL TREATMENTSHALL BE
 APPLIED UNDER ALL EXTERIOR CONCRETE ON
 GRADE WITHIN (1) FOOT OF THE PRIMARY
 STRUCTURE SIDEWALLS (PATIO).
  
 4)- SBC 1606.2.6.2 COMPONENTS & CLADDING
 ALL GLAZED OPENINGS (WINDOWS & DOORS)
 ARE REQUIRED TO WITH TESTING FOR WIND,
 A 10 SECOND PERIOD AT LOAD EQUAL TO 1.5
 TIMES THE DESIGN PRESSURE (1707.4).
  
 5)- SBC 1707.5 CONCRETE ROOF TILE,
 REQUIRES TESTING FOR RESISTANCE FOR OVER
 TURNING IN ACCORDANCE WITH THE SBCCI
 SSTD 11, THE CITY ACCEPTS SBCCI REPORTS
 OR DADE COUNTY PRODUCT APPROVALS.
  
 6)- SBC 1606.4.1/1707.4.1.: GLAZED OPEN-
 INGS REQUIRE PRODUCT TESTING FOR LARGE
 MISSLE RESISTANCE TESTING OR STORM
 SHUTTERS THAT HAVE BEEN TESTED, A COPY
 OF THE CITIES POLICY IS ENCLOSED,WITH A
 SAMPLE SCHEDULE. THE DESIGN CERTIFICA-
 TION SHEET INDICATES THAT THIS REQUIRE-
 MENT WILL BE "BY OTHERS". A SEPERATE
 PERMIT & FEES WILL BE ASSESSED IF THIS
 REQUIREMENT IS MET AFTER THE ISSUANCE OF
 THE BUILDING PERMIT.
  
 7)- PLANS WILL BE REQUIRED TO HAVE
 COUNTY IMPACT FEE STAMPS BEFORE THE
 ISSUANCE OF THE PERMIT.
  
 8)- STATE RADON CHARGES OF $5.68 WILL BE
 ASSESSED BY THE CITY.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 EX 8412


Account Summary | Usage Policy | Privacy Policy