| Plan Review Notes For Permit 01030400 |
| Permit Number |
01030400 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-03-24 00:00:00 | DENIED; | | | | | | 1.WATER HEATER SHALL BE READLY ACCESIBLE | | | CABINET SHALL HAVE A HINGED DOOR WITH | | | KNOB. | | | | | | 2.PLANS DO NOT MEET MINIMUM PLUMBING | | | FACILITYS. SEE94 SPC TABLE 407. | | | | | | 3.PAGE P-2 NOTES | | | 1.PLUMBING CODE SHOULD BE 94 SPC. | | | 5.BATHROOM FLOOR DRAINS REQUIRE | | | TRAP PRIMERS SEC. 409.4.1.1. | | | 6.CONDENSATE FROM A/C UNITS SHALL | | | GO TO STORM SEWER OR DRY WELL NOT | | | INTO SANITARY. UTILITY ORD. | | | 7.AIR CHAMBERS TO BE ENGINEERED | | | PER 607.8.2 AND 607.8.3. | | | 10.FIXTURES TO COMPLY TO TABLE 406. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8377 |
|