Plan Review Notes
Plan Review Notes For Permit 01030199
Permit Number 01030199
Review Stop R
Sequence Number 3
Notes
Date Text
2001-07-20 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE A5. WILL NEED TO PROVIDE
 ELEVATION CERTIFICATE. 7.5' MINIMUM
 ELEVATION PER CHAPTER 12 OF CITY CODE.
 2-REVISE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM:
 A)THE MEAN ROOF HEIGHT AND VELOCITY
 PRESSURE DON'T MATCH. SEE TABLE
 1606.2A OF SBC 1997.
 B)THE MEAN ROOF HEIGHT FOR MAIN HOUSE IS
 INCORRECT. MEAN ROOF HEIGHT SHALL BE
 TAKEN FROM THE AVEARAGE POINT OF THE
 HIGHEST ROOF OF THE HOUSE TO THE GRADE
 3-REVISE FRAMING DETAIL FOR OVAL WINDOW.
 NEED DIAGONAL STRUCTURAL BUCK IN ORDER
 TO INSTALL WINDOW AS PER PRODUCT
 APPROVAL. SEE PRODUCT APPROVAL.
 4-PRIOR TO INSTALLATION PROVIDE PRODUCT
 APPROVAL FOR:
 A)FRENCH DOORS WITH THREE PANELS AS
 SHOWN ON ARCHITECTURAL DRAWINGS.
 B)ENTRY DOOR WITH SIDELITES SINGLE
 ASSEMBLY AS SHOWN ON ARCHITECTURAL
 PLANS.