| Plan Review Notes For Permit 01030199 |
| Permit Number |
01030199 |
|
| Review Stop |
R |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2001-07-20 00:00:00 | APPROVED WITH PROVISO: | | | 1-FLOOD ZONE A5. WILL NEED TO PROVIDE | | | ELEVATION CERTIFICATE. 7.5' MINIMUM | | | ELEVATION PER CHAPTER 12 OF CITY CODE. | | | 2-REVISE THE DESIGN CERTIFICATION FOR | | | BUILDING CODE COMPLIANCE FORM: | | | A)THE MEAN ROOF HEIGHT AND VELOCITY | | | PRESSURE DON'T MATCH. SEE TABLE | | | 1606.2A OF SBC 1997. | | | B)THE MEAN ROOF HEIGHT FOR MAIN HOUSE IS | | | INCORRECT. MEAN ROOF HEIGHT SHALL BE | | | TAKEN FROM THE AVEARAGE POINT OF THE | | | HIGHEST ROOF OF THE HOUSE TO THE GRADE | | | 3-REVISE FRAMING DETAIL FOR OVAL WINDOW. | | | NEED DIAGONAL STRUCTURAL BUCK IN ORDER | | | TO INSTALL WINDOW AS PER PRODUCT | | | APPROVAL. SEE PRODUCT APPROVAL. | | | 4-PRIOR TO INSTALLATION PROVIDE PRODUCT | | | APPROVAL FOR: | | | A)FRENCH DOORS WITH THREE PANELS AS | | | SHOWN ON ARCHITECTURAL DRAWINGS. | | | B)ENTRY DOOR WITH SIDELITES SINGLE | | | ASSEMBLY AS SHOWN ON ARCHITECTURAL | | | PLANS. |
|