Notes
Date Text
2001-03-07 00:00:00FAILED:
 1. THE "APPLICATION FOR COSTRUCTION
 WITHIN PUBLIC R.O.W MUST BE SUBMITTED TO
 CITY ENGINEERS OFFICE PRIOR TO COMMENCE-
 MENT OF ANY WORK IN PUBLIC R.O.W.
 2. SUBMIT CONSTRUCTION PLANS, DETAILS,
 SPECIFICATION, HYDRAULIC, STORM WARTER
 CALCULATION AND ALSO SUBMIT PERVIOUS &
 IMPERVIOUS CALCULATION ON 8 1/2 X 11
 SHEETS WHICH INCLUDE NAME, ADDRESS,
 PROPERTY CONTROL NUMBER SIGNED AND
 SEALED BY DESIGN ENGINEER TO:
 1000 45TH STREET SUITE # 15
 WEST PALM BEACH, FL 33407
 3. A TRUCK WASHOUT AREA SHOULD BE ADDED
 TO SITE PLAN AT EXITS AND MAINTAINED
 DURING CONSTRUCTION.
 4. ALL BROKEN SIDEWALK, CURBS(& GUTTERS)
 ALONG THE PROPERTY (ALL SIDES) SHOULD BE
 REPLACED.
 5. ALL DRIVEWAYS THAT WILL NOT BE USED
 MUST BE REMOVED AND REPLACED WITH
 REGULAR CURBS (& GUTTERS).
 6. ALL DRIVEWAY MUST BE CONSTRUCTED PER
 CITY OF WPB STANDARD.
 7. SHOW CLEAN OUT LOCATION ON SANITARY
 SEWER LATERAL, ON THE PROPERTY AT BACK
 OF THE SIDEWALK IF POSSIBLE.
 8. SHOW LOCATION OF DUMPSTER IF KNOWN.
 9. IF KITCHEN FACILITIES ARE PLANED,
 THEN OIL SEPARATORS WILL NEED TO BE
 INSTALLED TO MEET THE CITY WASTEWATER
 DISCHARGE ORDINANCE.
 10. LOCATION OF METERS AND BACKFLOW
 PREVENTERS TO BE COORDINATED WITH THE
 CITY.
 11. DISCHARGE INTO THE INTERCOASTAL
 WATER WAY SHOULD BE MAINTAINED AT PRE-
 BUILDING RATES.
 12. PERMITS FROM SFWMD AND DEP MUST BE
 OBTAINED FOR DISCHARGING INTO THE
 INTERCOASTAL WATER WAY.
 13. SANITARY MANHOLES ON SHEET C4 ARE
 LABELED SM-1 THROUGH SM-3.PROFILE FOR
 SANITARY SEWER ON SHEET C8, THEY ARE
 LABELED MH-1 THROUGH MH-4 AND SM-4 IS
 MISSING ON SHEET C4, PLEASE VERIFY.
 14. ADD NOTES INDICATING THE REQUIRED
 CLEARANCES FOR WATER CROSSING OVER
 STORM OR SANITARY LINES AND IN CASE OF
 CONFILECT.
 15. PROVIDE CHARTS, DETAILS FOR THRUST
 BLOCKS.
 16. FOR STANDARD DETAILS CONTACT 561-
 659-8088 EXT. 2303
 17. PROVIDE ADDITIONAL INFORMATIONS AND
 SCHEDULES FOR REMOVAL OF EXISTING
 CONCRETE RETAINING WALL.
 17. A SEPARATE PERMITS APPLICATION
 MUST BE SUBMITTED TO CONSTRUCTION
 SERVICES (B&Z) FOR REMOVAL OF EXISTING
 CONCRETE RETAINIG WALL.