| Date |
Text |
| 2001-04-18 00:00:00 | APPROVED WITH PROVISO (NOTE: THIS ITEMS |
| | TO BE PROVIDED BEFORE INSTALLATION OR |
| | CONSTRUCTION): |
| | |
| | 1-PROVIDE PRODUCT APPROVAL FOR: |
| | -ENTRY DOORS WITH TRANSOM ABOVE SINGLE |
| | ASSEMBLY (OR PROFESSIONAL ENGINEER OF |
| | RECORD TO PROVIDE STRUCTURAL DETAIL |
| | SHOWING CONSTRUCTION OF LINTEL BETWEEN |
| | DOORS AND ARCHED TRANSOM WINDOW) |
| | -SINGLE HUNG WINDOWS PRODUCT APPROVAL |
| | IS MISSING SOME DRAWINGS. RESUBMIT. |
| | -ARCHED WINDOW PRODUCT APPROVAL IS |
| | MISSING DRAWINGS TOO. |
| | -SLIDING GLASS DOORS. |
| | -SLIDING GLASS DOORS WITH TRANSOM ABOVE |
| | SINGLE ASSEMBLY (OR STRUCTURAL DETAIL |
| | BY ENGINEER OF RECORD). |
| | -FIXED TRANSOM WINDOW |
| | -WINDOW MULLIONS. |
| | -GARAGE DOOR THAT MEET THE DESIGN |
| | PRESSURES CALCULATED BY THE ENGINEER |
| | OF RECORD (37PSF). |
| | |
| | 2-ENGINEER OF RECORD TO PROVIDE |
| | STRUCTURAL BUCK DETAIL USING A 2X |
| | BUCK AS REQUIRED ON PRODUCT APPROVAL |
| | FOR DOORS AND WINDOWS. |
| | |
| | 3-TRUSS ENGINEER TO SIGN, SEAL AND DATE |
| | THE TRUSS LAYOUT AND PROVIDE COMPLETE |
| | SET OF ENGINEERED TRUSSES AS WELL. |
| | -NOTE: ENGINEER OF RECORD TO REVIEW ALL |
| | TRUSS DRAWINGS PRIOR TO |
| | SUBMITTAL TO THIS OFFICE. |
| | |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ AT 659-8096 EXT. 8232. |