2001-03-27 00:00:00CHECKLIST:
 1-PROVIDE ORIGINAL SURVEY SIGNED, SEALED
 AND DATED BY THE PROFESSIONAL SURVEYOR
 AS REQUIRED BY FLORIDA STATUTES, 471
 -PROVIDE SURVEY THAT SHOWS REAR PORCH
 AS SHOWN ON ENGINEER'S PLANS.
 2-PROVIDE COMPLETE BEAM AND LINTEL
 SCHEDULE.
 -PROVIDE COMPLETE COLUMN SCHEDULE.
 SECTION 104.2.2 CITY AMENDMENTS.
 3-REAR ELEVATION EXCEEDS THE AMOUNT OF
 OPENINGS ALLOWED BY TABLE 600 SBC/97.
 4-PROVIDE COMPLETE FRAMING DETAILS FOR
 ARCHED OPENINGS.
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
  
 5-PROVIDE COMPLETE INFORMATION FOR
 CONSTRUCTION OF PLANTERS AT FRONT OF
 THE HOUSE.SEC 104.2.2 CITY AMENDMENTS
 6-PROVIDE SAFETY GLASS WHERE REQUIRED BY
 SEC. 2405.2 SBC 1997. SEE PLANS.
  
  
 7-SIZE OF ATTIC ACCESS IN HALLWAY TO BE
 22"X36" MIN. SEC. 2309.6 SBC 1997.
 8-SHOW ALL MASONRY OPENINGS AND HOW ARE
 THEY REINFORCED AT THE ENDS.
 -SPECIFY HOW ARE THE WINDOW SILLS
 CONSTRUCTED.
 SEC 104.2.2 CITY AMENDMENTS TO SBC/97.
 9-SPECIFY THE DESIGN PRESSURES
 CALCULATED FOR THE EXTERIOR OPENINGS.
 SECTION 1606 SBC 1997.
 10-SPECIFY COLUMNS TO SUPPORT TRUSS
 GIRDERS AT THE ENDS. SEC 104.2.2 OF
 CITY AMENDMENTS TO SBC/97. SEE PLANS.
 11-SPECIFY VENTILATION AT TOILETS AS
 REQUIRED BY SEC. 1203.4.2 AND 1203.1
 OF SBC 1997.
 12-SPECIFY CEILING INSTALLATION AT REAR
 AND ENTRY PORCH AS REQUIRED BY SEC.
 2504.2 SBC 1997. SEE APPLICATION
 REQUIREMENTS OF ASTM C926 AND ASTM
 C1063.
 13-SPECIFY CEILING FANS AS REQUIRED BY
 TABLE 6-6 FLORIDA ENERGY EFFICIENCY
 CODE FOR BUILDING CONSTRUCTION, 1997.
 14-SPECIFY SIZE OF ROOF VENTS TO COMPLY
 WITH SEC. 2309.7 SBC 1997.
 15-REVISE WALL SECTIONS. FOOTINGS TO BE
 12" MINIMUM BELOW FINISH GRADE AS
 REQUIRED BY SEC. 1804.1.3 SBC 1997.
 16-WALL SECTIONS AND FOUNDATION PLANS
 DON'T MATCH. CHECK SIZES OF FOOTINGS
 AND REINFORCEMENT, ETC.
 17-PROVIDE CONNECTION DETAIL OF WOOD
 BEAM TO CONCRETE BLOCK COLUMN AT
 CORNERS OF ENTRY PORCH. SECTION
 104.2.2 CITY AMENDMENTS TO SBC 1997.
 18-STORM PANELS:
 -PROVIDE COMPLETE INSTALLATION
 SCHEDULE AS PER CITY SAMPLE ATTACHED.
 -PROVIDE KEY PLAN SHOWING LOCATION OF
 STORM PANELS.
 -CLEARLY INDICATE ON STORM PANEL
 DRAWINGS MOUNTING CONDITIONS AND
 ANCHOR TYPE AND SPACING TO BE USED
 ACCORDING TO THE MEAN ROOF HEIGHT,
 DESIGN PRESSURES, PANEL SPAN, EDGE
 DISTANCE, CONNECTION TYPE AND
 STRUCTURE TO BE ATTACHED TO (CONCRETE
 BLOCK OR WOOD).
 19-PROVIDE PRODUCT APPROVAL FOR:
 -OUTSWING ENTRY DOORS WITH TRANSOM
 ABOVE SINGLE ASSEMBLY AS SHOWN ON
 FRONT ELEVATION. NOTE: IF DOORS AND
 WINDOW ABOVE ARE SEPARATED BY A LINTEL
 THEN, ENGINEER TO SPECIFY LINTEL ON
 HIS DRAWINGS.
 ALSO, MISSING THE APPROVED DRAWINGS.
 -DRAWINGS FOR SINGLE HUNG PRODUCT
 APPROVAL ARE NOT LEGIBLE.
 -SLIDING GLASS DOORS WITH TRANSOM
 ABOVE SINGLE ASSEMBLY OR ENGINEER TO
 SHOW IN HIS DRAWINGS A LINTEL IN
 BETWEEN DOORS AND WINDOW ABOVE.
 -HALF ROUND WINDOWS.
 -WINDOW MULLIONS.
 20-SEE ADDITIONAL COMMENTS ON PLANS.
 NOTE: PLEASE RETURN REVIEWED SET AFTER
 CORRECTIONS ARE DONE TO ORIGINAL
 DRAWINGS, IN ORDER TO EXPEDITE THE
 REVIEW PROCESS.
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.