| 2001-03-27 00:00:00 | CHECKLIST: |
| | 1-PROVIDE ORIGINAL SURVEY SIGNED, SEALED |
| | AND DATED BY THE PROFESSIONAL SURVEYOR |
| | AS REQUIRED BY FLORIDA STATUTES, 471 |
| | -PROVIDE SURVEY THAT SHOWS REAR PORCH |
| | AS SHOWN ON ENGINEER'S PLANS. |
| | 2-PROVIDE COMPLETE BEAM AND LINTEL |
| | SCHEDULE. |
| | -PROVIDE COMPLETE COLUMN SCHEDULE. |
| | SECTION 104.2.2 CITY AMENDMENTS. |
| | 3-REAR ELEVATION EXCEEDS THE AMOUNT OF |
| | OPENINGS ALLOWED BY TABLE 600 SBC/97. |
| | 4-PROVIDE COMPLETE FRAMING DETAILS FOR |
| | ARCHED OPENINGS. |
| | SEC. 104.2.2 CITY AMENDMENTS TO SBC/97 |
| | |
| | 5-PROVIDE COMPLETE INFORMATION FOR |
| | CONSTRUCTION OF PLANTERS AT FRONT OF |
| | THE HOUSE.SEC 104.2.2 CITY AMENDMENTS |
| | 6-PROVIDE SAFETY GLASS WHERE REQUIRED BY |
| | SEC. 2405.2 SBC 1997. SEE PLANS. |
| | |
| | |
| | 7-SIZE OF ATTIC ACCESS IN HALLWAY TO BE |
| | 22"X36" MIN. SEC. 2309.6 SBC 1997. |
| | 8-SHOW ALL MASONRY OPENINGS AND HOW ARE |
| | THEY REINFORCED AT THE ENDS. |
| | -SPECIFY HOW ARE THE WINDOW SILLS |
| | CONSTRUCTED. |
| | SEC 104.2.2 CITY AMENDMENTS TO SBC/97. |
| | 9-SPECIFY THE DESIGN PRESSURES |
| | CALCULATED FOR THE EXTERIOR OPENINGS. |
| | SECTION 1606 SBC 1997. |
| | 10-SPECIFY COLUMNS TO SUPPORT TRUSS |
| | GIRDERS AT THE ENDS. SEC 104.2.2 OF |
| | CITY AMENDMENTS TO SBC/97. SEE PLANS. |
| | 11-SPECIFY VENTILATION AT TOILETS AS |
| | REQUIRED BY SEC. 1203.4.2 AND 1203.1 |
| | OF SBC 1997. |
| | 12-SPECIFY CEILING INSTALLATION AT REAR |
| | AND ENTRY PORCH AS REQUIRED BY SEC. |
| | 2504.2 SBC 1997. SEE APPLICATION |
| | REQUIREMENTS OF ASTM C926 AND ASTM |
| | C1063. |
| | 13-SPECIFY CEILING FANS AS REQUIRED BY |
| | TABLE 6-6 FLORIDA ENERGY EFFICIENCY |
| | CODE FOR BUILDING CONSTRUCTION, 1997. |
| | 14-SPECIFY SIZE OF ROOF VENTS TO COMPLY |
| | WITH SEC. 2309.7 SBC 1997. |
| | 15-REVISE WALL SECTIONS. FOOTINGS TO BE |
| | 12" MINIMUM BELOW FINISH GRADE AS |
| | REQUIRED BY SEC. 1804.1.3 SBC 1997. |
| | 16-WALL SECTIONS AND FOUNDATION PLANS |
| | DON'T MATCH. CHECK SIZES OF FOOTINGS |
| | AND REINFORCEMENT, ETC. |
| | 17-PROVIDE CONNECTION DETAIL OF WOOD |
| | BEAM TO CONCRETE BLOCK COLUMN AT |
| | CORNERS OF ENTRY PORCH. SECTION |
| | 104.2.2 CITY AMENDMENTS TO SBC 1997. |
| | 18-STORM PANELS: |
| | -PROVIDE COMPLETE INSTALLATION |
| | SCHEDULE AS PER CITY SAMPLE ATTACHED. |
| | -PROVIDE KEY PLAN SHOWING LOCATION OF |
| | STORM PANELS. |
| | -CLEARLY INDICATE ON STORM PANEL |
| | DRAWINGS MOUNTING CONDITIONS AND |
| | ANCHOR TYPE AND SPACING TO BE USED |
| | ACCORDING TO THE MEAN ROOF HEIGHT, |
| | DESIGN PRESSURES, PANEL SPAN, EDGE |
| | DISTANCE, CONNECTION TYPE AND |
| | STRUCTURE TO BE ATTACHED TO (CONCRETE |
| | BLOCK OR WOOD). |
| | 19-PROVIDE PRODUCT APPROVAL FOR: |
| | -OUTSWING ENTRY DOORS WITH TRANSOM |
| | ABOVE SINGLE ASSEMBLY AS SHOWN ON |
| | FRONT ELEVATION. NOTE: IF DOORS AND |
| | WINDOW ABOVE ARE SEPARATED BY A LINTEL |
| | THEN, ENGINEER TO SPECIFY LINTEL ON |
| | HIS DRAWINGS. |
| | ALSO, MISSING THE APPROVED DRAWINGS. |
| | -DRAWINGS FOR SINGLE HUNG PRODUCT |
| | APPROVAL ARE NOT LEGIBLE. |
| | -SLIDING GLASS DOORS WITH TRANSOM |
| | ABOVE SINGLE ASSEMBLY OR ENGINEER TO |
| | SHOW IN HIS DRAWINGS A LINTEL IN |
| | BETWEEN DOORS AND WINDOW ABOVE. |
| | -HALF ROUND WINDOWS. |
| | -WINDOW MULLIONS. |
| | 20-SEE ADDITIONAL COMMENTS ON PLANS. |
| | NOTE: PLEASE RETURN REVIEWED SET AFTER |
| | CORRECTIONS ARE DONE TO ORIGINAL |
| | DRAWINGS, IN ORDER TO EXPEDITE THE |
| | REVIEW PROCESS. |
| | |
| | |
| | |