| Plan Review Notes For Permit 01020747 |
| Permit Number |
01020747 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-03-04 00:00:00 | PLUMBING PLAN REVIEWDENIED | | | REFERENCESSTD PLBG CODE-94 FACBC 97 | | | (1) SHT A-201 CONTACT DEPT.OF BUSINESS | | | REGULATION,HOTEL & RESTAURANT DIVISION. | | | PRIOR TO PLBG PLAN REVIEW, FOR THEIR | | | COMMENTS & REVIEW.954 958-5520. | | | (2) SHT A-201 REST RM.#1,2, SHOW 5' | | | TURNING RADIUS,NOT CUTTING INTO WATER | | | CLOSET CLEAR FLR SPACE. SEC 4.16.2 | | | (3) SHT A-201 DRINKING FOUNTAIN , MAKE | | | PROVISION FOR PEOPLE WHO HAVE TROUBLE | | | BENDING SEC 4.1.3 (10) (A) CUP DISPENSER | | | (4)SHT P-2 WATER HEATER TO BE READLY | | | ACCESSIBLE,SEC501.7 SHOW A DETAIL OF A | | | WORKING PLAT FORM WITH FIXED SHIPS | | | LADDER IN PLACE. | | | (5) SHT P-3 ALL INDIRECT WASTE TO FLOOR | | | SINKS SEC 802, NO HUB DRAINS. | | | (6) SHT P-3 AIR CHAMBERS, COMPLY WITH | | | SEC 607.8.3 ACCESSIBLE & RE-CHARGE-ABLE. | | | (7) SHT P-3 PLUMBING NOTE #5 DWV IN THIS | | | BUILDING HAS BEEN SCH 40 PVC PIPE. | | | END OF COMMENTS,PAUL SCHMITZ,QUESTIONS | | | 561-659-8096 X 8233 |
|