| Plan Review Notes For Permit 01011254 |
| Permit Number |
01011254 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-06-14 00:00:00 | *************BUILDING UNSAT************* | | | REVISION TO ADD CHIMNEY SURROUND | | | | | | ADDITIONAL INFORMATION IS REQUIRED | | | PER 97 SBC SECT.102.4.1. | | | | | | 1) PROVIDE DETAIL OF CEILING INSULATION | | | AT PROPOSED CHIMNEY THAT COMPLIES WITH | | | FL ENERGY CODE. | | | | | | 2) INDICATE IF CHIMNEY IS TO BE | | | FUNCTIONING OR NOT. IF FUNCTIONAL, | | | INDICATE PURPOSE FOR WHICH IT WILL BE | | | USED AND PROVIDE ALL PERTINENT | | | INFORMATION FOR FLUE AND APPLIANCE. | | | | | | 3) INDICATE OVERALL HEIGHT OF THIS | | | STRUCTURE. | | | | | | 4) INDICATE WALL AND ROOFING MATERIALS. | | | (COMPONENTS AND CLADDING) | | | | | | 5) INDICATE FIREBLOCKING & | | | DRAFTSTOPPINGBETWEEN CHIMNEY AND ATTIC | | | SPACE. | | | | | | 6) PROVIDE STRUCTRAL DESIGN | | | CALCULATIONS FOR BEARING, UPLIFT AND | | | MOMENT. | | | | | | 7) INDICATE THE TYPE AND LOCATION OF | | | CONNECTORS USED TO SUPPORT AND PROVIDE | | | CONTINOUS TIE TO STRUCTURE. | | | | | | 8) PROVIDE STRUCTURAL ANALYSIS OF | | | TRUSSES TO ENSURE THEIR ABILITY TO | | | HANDLE THE ADDITIONAL LOADS THAT WILL | | | BE IMPOSED BY THE CHIMNEY SURROUND. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|