| Date |
Text |
| 2001-06-04 00:00:00 | *************BUILDING UNSAT************* |
| | |
| | 1) BEFORE A PERMIT TO CONSTRUCT CAN BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALMBEACH CO.,THE PERMIT PLANS STAMPED |
| | BY |
| | THEM AND THE RECEIPT ATTACHED TO THE |
| | PERMIT APPLICATION. |
| | SBC 104.2.2 |
| | |
| | 2) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 3) THE DESIGN CERTIFICATION FORM |
| | CONTAINS INCORRECT DATA. THE ACCEPTED |
| | DESIGN STANDARDS FOR THE CITY OF WEST |
| | PALM BEACH ARE ASCE 7-95 OR 97 STANDARD |
| | BUILDING CODE (CHAPTER 16). THE |
| | IMPORTANCE FACTOR FOR 1997 SBC IS 1.0 & |
| | THE WIND SPEED IS 110 MPH. PLEASE |
| | REVIEWAND CORRECT THE FORM. |
| | |
| | 4) THE WINDOW AND DOOR DESIGN PRESSURE |
| | SCHEDULE WAS CALCULATED USING ASCE |
| | 7-93,THIS IS NOT AN ACCEPTED DESIGN |
| | STANDARD OF THE CITY OF WPB. PLEASE USE |
| | EITHER |
| | 97 SBC SECTION 1606 OR ASCE 7-95 FOR |
| | DESIGN CALCULATIONS. |
| | |
| | 5) SITE SPECIFIC ENGINEERING (PRODUCT |
| | APPROVAL) FOR BENCHMARK & LEGEND |
| | EXTERIOR DOOR MUST HAVE THE ORIGIONAL |
| | WET SIGNATURE (NOT A COPY), EMBOSSED |
| | SEAL AND DATE OF THE ENGINEER CERTIFYING |
| | THE PRODUCT AND THE WET SIGNATURE, |
| | EMBOSSED SEAL AND DATE OF THE DESIGNER |
| | OF RECORD OF THE STRUCTURE. ALSO THE JOB |
| | /SITE LOCATION IS REQUIRED.(SEE CITY OF |
| | WPB FORM ATTACHED.) |
| | |
| | 6) PROVIDE ENGINEERING FOR BUTT GLASS |
| | ASSEMBLIES PER 1997 SBC 2406.2. |
| | DETAILED SHOP DRAWINGS, SPECIFICATIONS & |
| | RATIONAL ANALYSIS PREPARED BY ENGINEER |
| | EXPERIENCED IN THIS WORK IS REQUIRED. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)659-8096 EXT.8202 |