Plan Review Notes
Plan Review Notes For Permit 01010657
Permit Number 01010657
Review Stop R
Sequence Number 1
Notes
Date Text
2001-02-05 00:00:00DENIED
  
 1)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND OF THE
 DESIGN PROFESSIONAL OF RECORD.
  
 4) FOUNDATION FOR PRIVACY WALL AT REAR
 OF STRUCTURE AS SHOWN IN DETAIL 1 ON
 SHEET A-8 WILL ENCROACH ON ADJACENT
 LOT AT ZERO LOT LINE. PLEASE REVISE.
  
 5) ONE HOUR RATED GLASS BLOCK IS
 REQUIRED AT ZERO LOT LINE. 2112.1.2 OF
 1997 SBC.
  
 6) THE ONE (1) EGRESS DOOR REQUIRED IS
 TO BE OF THE SIDE SWINGING TYPE AND
 PROVIDE NOT LESS THAN A 32" WIDE CLEAR
 OPENING. 1997 SBC 1012.1
  
 7) EXTERIOR WALL LOCATIONS ON SITE PLAN
 S-1 DO NOT CORRESPOND WITH THE OTHER
 DRAWINGS. PLEASE CORRECT.
  
 8) THE MEAN ROOF HEIGHT LISTED ON THE
 DESIGN COMPLIANCE FORM AS 15' IS NOT
 CORRECT,THE ACTUAL MEAN ROOF HEIGHT IS
 APPROXIMATELY 22'. THIS WILL CHANGE THE
 BASIC VELOCITY PRESSURE. PLEASE CORRECT.
  
 9) PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 FOR:
 - ARCHED FIXED GLASS WINDOWS
 - SLIDING GLASS DOORS
  
 10)PROVIDE MANUFACTURER'S SPECIFICATIONS
 AND UL LISTNG FOR BBQ.
  
 11)PROVIDE REVISED INSTALLATION SCHEDULE
 AND KEY PLAN THAT CORRESPONDS WITH PLANS
  
 12)PROVIDE ENGINEERING FOR BUTT GLASS
 ASSEMBLY PER 97 SBC 2406.2.
  
  
 IF YOU HAVE QUESTIONS CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202