| 2001-01-23 00:00:00 | DENIED; | | | | | | 1.MOP SINK IS IN THE ACCESSIBLE ROUTE | | | OF THE BATHROOM 97 FACBC 4.3. | | | | | | 2.WATER HEATER MUST BE READILY | | | ACCESSIBLE 94 SPC 501.7. INSTALL W/H | | | ON FLOOR OR INSTALL A FIXED SHIPS | | | LADDER. | | | | | | 3.3" FLOOR DRAIN WITH TRAP PRIMER | | | REQUIRED IN RESTROOM. SPC 409.4.1.1. | | | | | | 4.BATHROOM CANNOT OPEN DIRECTLY INTO | | | A ROOM USED FOR THE PREPARATION OF | | | FOOD FOR THE PREPARATION OF FOOD FOR | | | SERVICE TO THE PUBLIC SPC 404.2. | | | | | | 5.(AIR CHAMBER DETAIL) AIR CHAMBERS | | | SHALL COMPLY WITH SPC 607.8.1. MUST | | | BE ENGINEERED OR CALCULATED AND COMPLY | | | WITH 607.8.3. THEY MUST BE ACCESSIBLE. | | | | | | 6.SEPORATE GREASY WASTE LINE REQUIRED | | | FOR MOP SINK AND THE TWO FLOOR SINKS | | | AND RUN TO EXISTING GREASE TRAP. | | | | | | 7.A-3 WATER HEATER DETAIL SHOWS 50 GAL. | | | LOW BOY. WATER RISER SHOWS 20 GAL.W/H. | | | WHAT SIZE IS WATER HEATER. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT.8377 |
|