2001-01-22 00:00:00BUILDING PLAN REVIEW:
 1)- SBC 1203.4.1: TOILET ROOMS SHALL NOT
 OPEN DIRECTLY INTO A ROOM USED FOR THE
 PREPARATION OF FOOD FOR SERVICE TO THE
 PUBLIC.
 2)- SBC 1204.2 SURROUNDING MATERIALS:
 THE WALLS & FLOORS OF ALL PUBLIC REST-
 ROOMS SHALL BE LINED WITH NONABSORBENT
 MATERIAL TO A HEIGHT OF 4'-0" ABOVE THE
 FLOOR.
 3)- SBC 803.3 MINIMUM INTERIOR FINISH CL
 ASSIFICATION, AS PER ASTM E84. PROVIDE
 THE FLAMESPREAD AND THE SMOKE DEVELOP-
 MENT FOR THE INTERIOR FINISHES OR THE
 MINIMUM CLASSIFICATION OF MATERIALS TO
 BE USED.
 4)- FL ACCESSIBILITY CODE 4.13.6
 MANEUVERING CLEARENCES AT DOORS SEE FIG.
 #25 FOR DOORS TO RESTROOM.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 EX 8412