| Plan Review Notes For Permit 01010066 |
| Permit Number |
01010066 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-16 00:00:00 | DENIED | | | DENIED | | | | | | 1) PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR: | | | - NEW DINING ROOM WINDOWS | | | - ROOF COVERING FOR STORAGE BUILDING | | | | | | 2) PROVIDE MOISTURE BARRIER BETWEEN LATH | | | & STUCCO AND 5/8"CDX PLYWOOD AT DINING | | | ROOM WINDOWS. 97 SBC 2303.3 | | | | | | 3) SPECIFY TYPE OF EXTERIOR FINISH THAT | | | WILL BE APPLIED TO STORAGE BUILDING. | | | CLEARANCE BETWEEN WOOD SIDING AND EARTH | | | ON THE EXTERIOR OF A BUILDING SHALL BE | | | NOT LESS THAN 6 INCHES. CITY OF W.P.B. | | | AMENDMENTS TO 97 S.B.C. | | | | | | ROBERT MCDOUGAL | | | BUILDING PLAN REVIEW | | | (561) 659-8096 EXT.8202 |
|