| Date |
Text |
| 2001-02-15 00:00:00 | SECOND CHECKLIST: |
| | 1-IMPACT FEES ARE STILL NOT PAID. PAY |
| | IMPACT FEES TO PALM BEACH COUNTY AND |
| | BRING STAMPED DRAWINGS AND RECEIPT. |
| | 2-STORM PANELS INFORMATION IS STILL |
| | INCOMPLETE: |
| | -NEED KEY PLAN THAT MATCHES MODEL. |
| | -STORM PANEL DWG #01-246 CAN'T BE USED |
| | AS A REFERENCE BECAUSE IT IS NOT PART |
| | OF THE DRAWINGS APPROVED IN THE SBCCI |
| | EVALUATION REPORT. |
| | -SEE LIMITATIONS ON SHEET 3 OF 3 OF |
| | SBCCI REPORT REGARDING THE USE OF TRU- |
| | FAST TAP GRIP ANCHORS. CHECK THE MIN. |
| | COMPRESSIVE STRENGTH OF CONCRETE |
| | MASONRY UNITS. |
| | -CLEARLY INDICATE ON ANCHOR SCHEDULE |
| | THE SPECIFIC MOUNTING CONDITIONS AND |
| | ANCHOR TYPE AND SPACING TO BE USED |
| | ACCORDING TO THE DESIGN PRESSURES, |
| | MIN. EDGE DISTANCE, MAX. PANEL SPAN, |
| | CONNECTION TYPE AND STRUCTURE TO BE |
| | ATTACHED TO (NOTE: THIS IS CONCRETE |
| | BLOCK CONSTRUCTION, NOT CONCRETE). |
| | -ALL THIS INFORMATION MAY BE SUBMITTED |
| | UNDER A SEPARATE PERMIT. |
| | 3-PROVIDE CURRENT SBCCI OR DADE COUNTY |
| | PRODUCT APPROVAL FOR: |
| | -GARAGE SIDE DOOR. SEE SIZE SPECIFIED |
| | ON PLANS. |
| | -WINDOW MULLIONS, SINGLE HUNG WINDOWS, |
| | RECTANGULAR WINDOWS & ARCHED WINDOWS. |
| | NORANDEX PRODUCT APPROVAL IS NOT |
| | ACCEPTABLE UNLESS IT IS SIGNED, SEALED |
| | AND DATED BY THE ENGINEER OF RECORD |
| | FOR THIS SPECIFIC LOCATION. |
| | 4-PROVIDE SOIL TEST REPORT AS PER SEC. |
| | 1804.2.7 AND TABLE 1804.2.7.3 OF CITY |
| | AMENDMENTS TO SBC 1997. |
| | NOTE: THIS REPORT WAS NEVER SUBMITTED |
| | TO THE CITY FOR REVIEW. |
| | -ALSO, CLARIFY WHY DENSITY TEST |
| | SUBMITTED IS DONE WITH THE NAME OF |
| | ANOTHER BUILDER. |