| Plan Review Notes For Permit 00121116 |
| Permit Number |
00121116 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-09 00:00:00 | BUILDING PLAN REVIEW | | | 1). THE DRINKING FOUNTAIN IN THE VESTI- | | | BULE BLOCKS THE EGRESS OF THE RESTROOMS, | | | A REQUIRED 3'-0" IS THE MINIMUM ALLOWED | | | SEE SECTIONS SBC 1003.3.4/ 1003.2.3. | | | 2). THE PLANS CALL FOR THE TENANT SPACE | | | TO BE FIRE SPRINKLERED, SUBMIT PLANS & | | | CALCULATIONS FOR THE FIRE SPRINKLERS. | | | 3). SBC 803.2 INTERIOR FINISH MATERIALS | | | OTHER THANTHOSE APPLIED TO FLOORS | | | SHALL BE CLASSIFIED IN ACCORDANCE WITH | | | ASTM E 84. PLEASE SUBMIT A LIST OF FIN-I | | | SHES. | | | 4). SBC 1606.4.1- IMPACT GLAZING FROM | | | WINDBORN DEBRIS THE STOREFRONT GLAZING & | | | DOOR UNIT WILL REQUIRE PRODUCT TESTING, | | | 2 DADE COUNTY OR SBCCI REPORTSWILL BE | | | REQUIRED. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412 |
|