Plan Review Notes
Plan Review Notes For Permit 00120903
Permit Number 00120903
Review Stop FIRE
Sequence Number 2
Notes
Date Text
2001-02-09 00:00:001) THE FIRST FLOOR EXISTING LEASE SPACE
 FOR CHARTER SCHOOL GRADES K-1 (40
 STUDENTS) MUST EITHER HAVE A DOOR
 LEADING DIRECTLY TO THE EXTERIOR OF THE
 BUILDING OR A WINDOW FOR VENTILATION AND
 RESCUE.
 2) COPIES OF THE APPLICABLE CODE SECTION
 REGARDING VENTILATION AND RESCUE WINDOWS
 HAVE BEEN ATTACHED TO THE PLANS. THESE
 WINDOWS MUST BE NO HIGHER THAN 44
 INCHES ABOVE THE FLOOR.
 3) THE EXISTING JANITOR CLOSET TO BE
 PROTECTED BY A FIRE SPRINKLER SYSTEM
 USING THE DOMESTIC WATER SYSTEM.
 4) PROVISIONS ARE TO BE MADE FOR
 HANDICAPPED CHILDREN.
 5) PLEASE PROVIDE MORE DETAILS ON
 DEMOUNTABLE PARTITIONS. PLEASE PROVIDE
 PRODUCT APPROVALS.
  
 APPROVED PROVISO:
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910