| Plan Review Notes For Permit 00120608 |
| Permit Number |
00120608 |
|
| Review Stop |
ENG |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | PASSED WITH PROVISOS: | | | PHASE ONE OF ROAD WILL NEED TO BE | | | RESUBMITTED AT A LOWER ROAD ELEVATION TO | | | HAVE A ONE FOOT DIFFERENCE BETWEEN | | | THE EXISTING BUILDINGS FLOOR ELEVATION | | | AND CROWN OF ROAD. | | | THE PHASE ONE WATER MAIN CAN NOT BE | | | INSTALLED UNTIL A FINAL ROAD ELEVATION | | | IS SET DUE TO THE REQUIRED COVER (36"). | | | CONSTRUCTION OF STORM AND SANITARY CAN | | | PROCEED IN PHASE ONE. | | | ROAD CONSTRUCTION CAN NOT BE BUILT (BOTH | | | PHASES) INCLUDING SIDEWALKS, CURBS AND | | | GUTTERS AND PAVED SECTIONS, UNTIL STREET | | | LIGHT PLAN HAS BEEN PERMITTED SO THE | | | UNDERGROUND WIRING CAN GO IN. | | | THE GREASE TRAP, STORMWATER LINES AND BA | | | RESTAURANT MUST BE PERMITTED SEPARATELY | | | UNDER THE CHINESE RESTAURANT'S ADDRESS. | | | THE SERVICES IN THE ROAD FOR THE CHINESE | | | RESTAURANT CAN BE CONSTRUCTED UNDER THIS | | | PERMIT. | | | CONSTRUCTION OF THE WATER AND SANITARY | | | SEWER SYSTEM CAN NOT START TILL THE | | | DEP/PBC HEALTH DEPARTMENT HAVE PERMITTED | | | THE PROJECT. |
|