| 2001-01-08 00:00:00 | *************** UNSAT ***************** |
| | |
| | 1)NOTE: PLEASE SEE ELECTRICAL NOTE |
| | BELOW RISER. NOTE MENTIONS ALL OUTLETS |
| | WITHIN 6` OF WATER SOURCE. THAT WAS FROM |
| | THE "96" NEC. ALL OUTLET SERVING |
| | COUNTERPSPACE/ GARAGES/ BATHS ARE TO BE |
| | GFI/GFI PROTECTED. PER 210-8 |
| | PLEASE CHANGE OR REMOVE NOTE. |
| | |
| | 2)NOTE: PLEASE SEE RISER,,, PANEL"B " IS |
| | SHOWN ON RISER AS EXISTING. PLEASE SHOW |
| | LOCATION OF MAINS. MAINS NEED TO BE |
| | GROUPED PER 230-72 MAIN FOR PANEL "B" |
| | IS WHERE NOW? IF EXISTING WHAT DOES IT |
| | FEED? |
| | |
| | 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR |
| | ALL NEW EQUIPMENT BEING INSTALLED. MAINS |
| | /PANELS.BRKRS ARE ALL TO BE RAATED FOR |
| | THE AVAILABLE FAULT CURRENT PER 110-9 |
| | |
| | 4)NOTE; PLEASE SHOW ALL GROUNDING AT |
| | DETACHED POOL HOUSE PER 250-50. COLD |
| | WATER PIPE AND NEW BLDG STEEL. |
| | |
| | 5)NOTE: PLEASE SHOW MEANS OF DISCONNECT |
| | AT DETACHED BLDG. MCB? DISC? ETC. |
| | |
| | 6)NOTE: NOTE,, RISER SHOWS EQUIPMENT |
| | GROUNDING CONDUCTOR FROM METER TO MAIN |
| | /PANEL.PLEASE VERIFY. |
| | |
| | 7)NOTE: PLEASE SHOW MEANS OF EGRESS |
| | LIGHTING FROM GARAGE INTO STORAGE?" 210- |
| | -70. 3-WAY? |
| | |
| | |
| | PLEASE SUBMIT ALL THE ABOVE INFORMATION |
| | FOR REVIEW. IF THERE ARE ANY QUESTIONS |
| | PLEASE CALL. |
| | |
| | DEWEY PALMER |
| | ELECTRICAL PLAN REVIEW |
| | 659-8096 EXT 8372 |