| 2001-01-08 00:00:00 | BUILDING PLAN REVIEW: |
| | FLORIDA ACCESSIBILITY CODE: |
| | 1). PASSENGER LOADING ZONE: 4.6.6:ACCESS |
| | AISLE 60" X 20'-0". |
| | 2).RAMPS: ADMINISTRATIVE CODE104.2.2 |
| | DETAILS & DRAWINGS SHOWING STRUCTURAL |
| | DETAILS, SLOPE, LENGTH, GAURDRAIL DETAIL |
| | ENTRY DETAIL TO SALES TRAILER 4.13.8 |
| | FL. ACC. CODE RAMP TO SALES TRAILER |
| | TRANSSITION NOT TO EXCEED 3/4". |
| | LANDINGS 4.8.4.2:ALL LANDINGS ON RAMPS |
| | (BOTTOM OF RAMP)SHALL BE 72" OF STRAIGHT |
| | & LEVEL CLEARENCE. |
| | 3).FL. ACC. CODE 4.9.2: TREADS SHALL NOT |
| | BE LESS THAN 11" WIDE AND OPENRISERS |
| | ARE NOT PERMITTED. |
| | S.B.C.1007.3.1 THE SUM OF 2 RISERS & 1 |
| | TREAD SHALL NOT BE LESS THAN 24" & NOT |
| | MORE THAN 25". |
| | 4).ADMINISTRATIVE CODE 104.2.2: MOBILE |
| | HOMES (USED FOR RESIDENTIAL UNITS) DO |
| | NOT COMPLY WITH COMMERCIAL USAGE. SBC |
| | TABLE 1604.1 RESIDENTIAL SLEEPING 30 PSF |
| | LIVE LOAD VS 50 PSF OFFICES. THE DOORWAY |
| | HALLS & BATHROOM MUST COMPLY WITH FL. |
| | ACCESSIBILITY CODE WHICH RESIDENTIAL |
| | MOBILE HOMES DO NOT. |
| | S.S.553.35-553.42 MANUFACTURED BUILDINGS |
| | MOBILE COMPLY WITH STATE BUILDING STAND- |
| | ARDS.553.381 MANUFACTURES CERTIFICATION |
| | NUMBER. |
| | WE WILL NEED 2 SETS OF PRINTS, ALSO THE |
| | TIE DOWN PLANS. WE WILL NEED THE MAXIMUM |
| | PIER LOADS IN POUNDS BASED ON THE SOIL |
| | VALUES. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | (561) 659-8096 EX 8412. |