Plan Review Notes
Plan Review Notes For Permit 00120084
Permit Number 00120084
Review Stop R
Sequence Number 1
Notes
Date Text
2001-01-09 00:00:00CHECKLIST:
 1-SURVEY DOESN'T MATCH PLANS.
 -PLAT NEED TO BE RECORDED IN ORDER TO
 ISSUE ANY PERMITS.
 -UPDATE SURVEY AS REQUIRED WHEN PLAT IS
 RECORDED.
 2-PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING STAMPED DRAWINGS AND RECEIPT.
 3-ENGINEER OF RECORD TO PROVIDE ALL HIS
 INFORMATION ON DRAWINGS AS REQUIRED BY
 CHAPTER 471 OF FLORIDA STATUTES.
 4-PROVIDE CURRENT SBCCI OR DADE COUNTY
 PRODUCT APPROVAL FOR:
 -ENTRY DOOR WITH SIDELITE ASSEMBLY.
 -DOUBLE DOORS WITH TRANSOM ASSEMBLY.
 -SINGLE HUNG WINDOWS.
 -WINDOW MULLIONS.
 -GLASS BLOCK.
 -SLIDING GLASS DOORS.
 5-SPECIFY SAFETY GLASS AS REQUIRED. SEE
 PLANS AND SECTION 2405.2 SBC 1997.
 6-PROVIDE COMPLETE SET OF ENGINEERED
 DRAWINGS FOR "ROYAL WALL" SYSTEM FOR
 THIS SPECIFIC HOUSE.
 -INCLUDE ALL THE ENGINEER'S INFORMATION
 REQUIRED BY CHAPTER 471 FL. STATUTES.
 7-IF HOUSE IS TO BE LOCATED AT ZERO LOT
 LINE, THEN THE 2" CONCRETE THICKNESS
 OF ROYAL WALL SYSTEM DOESN'T PROVIDE
 ONE HOUR FIRE RATING.
 TABLE 709.2.1.1 OF SBC 1997.
 NOTE: THIS COMMENT WAS ADDRESSED ON
 PREVIOUS REVIEWS WHEN ROYAL WALL
 SYSTEMS WERE USED.
 8-ENERGY CALCULATIONS:
 -CLARIFY IF THIS IS A GENERIC MODEL
 CALLED ABACO. IF SO, THEN, ENERGY
 CALCS NEED TO BE FOR A WORST CASE.
 -COMPLETELY FILL TOP PORTION OF FORM.
 -PROVIDE ORIGINAL SIGNATURES AT BOTTOM
 OF FORM.
 9-STORM PANELS:
 -PROVIDE A KEY PLAN AND COMPLETE
 INSTALLATION SCHEDULE (AS PER CITY
 SAMPLE ATTACHED).
 -CLEARLY INDICATE ON DRAWINGS SPECIFIC
 MOUNTING CONDITIONS AND ANCHOR TYPE
 AND SPACING TO BE USED ACCORDING TO
 THE MEAN ROOF HEIGHT,DESIGN PRESSURES,
 PANEL SPAN, EDGE DISTANCE, CONNECTION
 TYPE AND STRUCTURE TO BE ATTACHED TO.
 10-SOIL TEST REPORT:
 -DOCUMENTS SUBMITTED FOR PUBLIC RECORDS
 SHALL HAVE THE ENGINEER'S ORIGINAL
 SIGNATURE. CHAPTER 471 FL. STATUTES.
 -PROVIDE COMPLETE SOIL TEST REPORT AS
 PER TABLE 1804.2.7.3 CITY AMENDMENTS.
 -PROVIDE FOOTING RECOMMENDATIONS.
 11-CONTRACTOR'S CONSTRUCTION VALUE IS
 VERY LOW. PERMIT FEES WILL BE ADJUSTED
 TO A MORE REALISTIC VALUE.
 12-DESIGN CERTIFICATION FOR BUILDING
 CODE COMPLIANCE FORM:
 -USE CITY FORM (ATTACHED).
 -REVISE MEAN ROOF HEIGHT AND VELOCITY
 PRESSURE AS REQUIRED.
 -FILL IN ENGINEER'S INFORMATION AT
 BOTTOM OF FORM.
 13-SEE ADDITIONAL COMMENTS ON PLANS.
  
 NOTES:
 -PLEASE RETURN REVIEWED SET AFTER THE
 CORRECTIONS ARE DONE TO THE ORIGINALS
 IN ORDER TO EXPEDITE THE REVIEW.
 -FOR QUESTIONS OR CLARIFICATIONS PLEASE
 CALL JULIO GOMEZ AT 659-8096 EXT. 8232.