| Date |
Text |
| 2001-01-08 00:00:00 | FAILED |
| | MUST COMPLY WITH THE FOLLOWING DEMANDS |
| | 1. PLEASE SHOW EXISTING WM ALONG 3' |
| | UTILITY EASEMENT AND SHOW NEW IRRIGATION |
| | METER SERVICE CONNECTION. |
| | 2. IT IS RECOMENDED THAT NEW IRRIGATION |
| | SERVICE BE MADE ON THE WATERMAIN OFF SUN |
| | SET ROADAND DIXIE. |
| | 3. DRIVEWAY ENTRANCES DO NOT COMPLY WITH |
| | CITY DRIVEWAY APPROACH STANDARDS |
| | EMAIL [email protected] |
| | FOR STANDARD DETAIL. |
| | 4. CALL OUT SIZE OF METER AND SIZE OF SE |
| | RVICE. WE ALLOW ONLY 1" OR 2" TYPE K |
| | COPPER. |
| | 5. PROVIDE CITY OF WPB |
| | PUBLIC UTILITY DEPT. WITH A MINIMUM OF 2 |
| | SETS OF PLANS FOR THEIR FILES. |
| | 6. DRAINAGE CALCULATIONS SHALL BE SUBMIT |
| | TED TO JOSE DEL RIOS OF THE STORM WATER |
| | DIVISION FORAPPROVAL. |
| | 7. NO LARGE STREES SHALL BE PLANTED IN |
| | UTILITY EASEMENT |
| | 8. PROVIDE OR CALL OUT HANDICAP RAMP FOR |
| | PARKING |
| | TOTAL SITE SF IS 19175OK |
| | TOTAL IMPERVIOUS SF IS 16154OK |
| | TOTAL PERVIOUS SF IS 3021OK |
| | 9. PROVIDE STANDARD UTILITY DETAILS |
| | THAT APPLY. YOU MAY REQUEST THESE VIA |
| | EMAIL TO THE SAME EMAIL AS ABOVE |
| | 10. A DESIGNATED PLAN SHOULD BE TITLED |
| | POLLUTION CONTROL PLAN AND SHALL SHOW |
| | A SILT FENCE ALONG THE PROPERTY LINE |
| | OF THE SITE. PLEASE PROVIDE A SILT |
| | FENCE DETAIL OR CUT SECTION. |
| | 11. ALL LARGE TREES MUST BE ATLEAST 5' |
| | AWAY FROM EXISTING WM'S |
| | 12. TO LOCATE EXISTING WM YOU MAY CONTAC |
| | T OUR UTILITY LOCATING DEPT. AT |
| | 659 8079. |
| | |
| | IF ANY QUESTION PLEASE FEEL |
| | FREE TO CONTACT ME AT |
| | 561 659 8040 |
| | PUBLIC UTILITIES ENGINEERING SERVICES |
| | 1000 45TH STREET SUITE 15 |
| | WPB, FL 33407 |
| | FAX 561 659 8039 |
| | |
| | HAVE A GREAT DAY!! |