| 2001-01-08 00:00:00 | CHECKLIST: |
| | 1-PAY IMPACT FEES TO PALM BEACH COUNTY |
| | AND BRING STAMPED DRAWINGS AND RECEIPT |
| | 2-ARCHITECT TO DATE DRAWINGS WHEN |
| | SUBMITTING FOR PUBLIC RECORDS. CHAPTER |
| | 481 FLORIDA STATUTES. |
| | 3-PROVIDE PRODUCT APPROVAL FOR: |
| | -ROOF TILE |
| | -SLIDING GLASS DOORS (PRODUCT APPROVAL |
| | SUBMITTED IS FOR 2 PANELS ONLY) |
| | -UL LISTING AND SPECS FOR BBQ. |
| | -SINGLE HUNG WINDOWS PRODUCT APPROVAL |
| | IS MISSING DRAWINGS. ALSO, MAKE SURE |
| | DRAWINGS ARE LEGIBLE WHEN RESUBMITTING |
| | 4-SPECIFY HOW IS VENTILATION PROVIDED TO |
| | STORAGE ROOM. PROVIDE HVAC DRAWINGS. |
| | SECTION 1203.1.4 SBC 1997. |
| | 5-PROVIDE SOIL TEST REPORT. |
| | 6-SEE ADDITIONAL COMMENTS ON PLANS AND |
| | REVISE ORIGINAL DRAWINGS AS REQUIRED. |
| | INCLUDING COMMENTS BY THE OTHER TRADES |
| | 7-ROOF FRAMING PLAN: SPECIFY UPLIFT |
| | CALCULATIONS AND PROVIDE TRUSS ANCHOR |
| | SCHEDULE. |
| | 8-REVISE DESIGN CERTIFICATION FOR WIND |
| | LOAD COMPLIANCE FORM (USE ATTACHED |
| | UPDATED FORM): |
| | -VELOCITY PRESSURE IS INCORRECT. SEE |
| | TABLE 1606.2A SBC 1997. |
| | -SBC DOESN'T USE THE COASTAL EXPOSURE. |
| | SEE CHAPTER 16 SBC 1997. |
| | -NEED ORIGINAL SIGNATURE AND DATE. |
| | CHAPTER 481 OF FLORIDA STATUTES. |
| | 9-PROVIDE LINTEL SCHEDULE. |
| | SECTION 104.2.2 CITY AMENDMENTS TO SBC |
| | 10-PROVIDE SURVEY WITH PROPOSED LAYOUT. |
| | SECTION 104.2.2 CITY AMENDMENTS. |
| | 11-OWNER TO SIGN AND DATE THE ENERGY |
| | CALCULATIONS. |
| | |
| | |
| | |
| | |
| | |
| | |
| | NOTES: |
| | - PLEASE RETURN REVIEWED SET AFTER THE |
| | CORRECTIONS ARE DONE TO ORIGINAL DWGS |
| | IN ORDER TO EXPEDITE THE REVIEW. |
| | - IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ AT 659-8096 EXT. 8232. |
| | - A/C DRAWINGS WERE SUBMITTED AFTER ALL |
| | REVIEWS WERE DONE. PLEASE RESUBMIT |
| | A/C DRAWINGS WHEN RESUBMITTING ALL |
| | PACKAGE. |