| Plan Review Notes For Permit 00110504 |
| Permit Number |
00110504 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2001-01-10 00:00:00 | BUILDING COMMENTS | | | ------------------- | | | | | | 1] | | | DRAWINGS SHALL BE REVIEWED FOR COUNTY | | | IMPACT FEES. | | | 2] | | | SECOND MEANS OF EGRESS SHALL COMPLY WITH | | | 1004.1,SBC, FIRE ESCAPE EXIT IS NOT | | | CONSIDERED AS AN APPROVED EGRESS. | | | 3] | | | EXTERIOR STAIR SHALL COMPLY WITH 1007.3 | | | AND 1007.4,SBC,[TREADS AND RISERS | | | RATIO,LANDIGS]. | | | 4] | | | SUBMIT DETAILS AND CALCULATIONS FOR | | | FLOOR LOADING AND WALKING SURFACE AT | | | SECOND LEVEL DECK AREA. | | | EXSISTING LOW WALL/GUARDRAIL SHALL | | | COMPLY WITH 1015.2 AND 1608.2,SBC. | | | 5] | | | 704.3.1,SBC, SUBMIT DETAILS OF EXSISTING | | | PARTITIONS,1HR TENENT SEPERATION. | | | 704.2.4 ALLOWS 1/2HR. CORRIDOR WALLS | | | WITH 20 MIN. DOORS, SUBMIT DETAILS. | | | | | | | | | REVIEWED BY: | | | LUIS MARTINEZ | | | 561-659-8096 | | | #8456 |
|