| Date |
Text |
| 2001-01-19 00:00:00 | BUILDING PLAN REVIEW: |
| | 1). FL. ACC. CODE 4.3.2.2- PROVIDE AN |
| | ACCESSIBLE ROUTE THROUGHOUT TO ALL |
| | LEVELS. A) HORSESHOE BENCH RAISED SEAT- |
| | ING 6 INCHES. |
| | B) BAR AREA UP ONE STEP, NO RAMP |
| | C) BENCH SEATS, RAISED WOOD |
| | PLATFORM 1'-0". |
| | 2) FL.ACC. CODE 4.3.2.2/SBC 1019.10.1.2 |
| | 44" ACCESS AILES IN FRONT OF HORSESHOE |
| | BENCH SEATING. |
| | 3) DISCREPANCY- LS-1 VS A101- ENTRANCE |
| | TO MENS /LADIES RESTROOMS. |
| | 4) FL.ACC. CODE 4.1.3.6 MENS RESTROOM |
| | ENTRY WILL REQUIRE 24" FOR SIDE EXIT. |
| | 5) DOOR #2 IS LISTED AS USE AS A EXIT |
| | DOOR, THIS IS PROHIBITED BY SBC 1012.1.2 |
| | EGRESS DOORS SHALL BE SIDE SWINGING DOOR |
| | DOORS SHALL SWING IN THE DIRECTION OF |
| | EGRESS WHEN SERVING AN OCCUPANT LOAD OF |
| | 50 OR MORE. |
| | 6) PROVIDE SITE PLAN TO SHOW SECOND EXIT |
| | IS PROTECTED THROUGH TO THE EXTERIOR. |
| | 7) SBC TABLE 705.1.2- EXIT ACCESS DOOR |
| | AT THE KITCHEN/ OFFICE AREA NEEDS TO |
| | BE A 20 MINUTE RATED DOOR, |
| | 8).SBC 1606.4.1/1707.4.1- ALL EXTERIOR |
| | GLAZING TO HAVE LARGE MISSLE IMPACT TEST |
| | ING BY DADE COUNTY OR SBCCI, REPORTS AS |
| | WELL AS THE TECHNICAL DRAWINGS THAT |
| | SUPPORT THE REPORT WILL BE REQUIRED. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | (561) 659-8096 |
| | 9) THE THIRD SET OF PLANS DOES NOT HAVE |
| | THE LIFE SAFETY PLAN IN IT. |