| Plan Review Notes For Permit 00110313 |
| Permit Number |
00110313 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | DENIED | | | | | | 1)RECORDED NOTICE OF COMMENCEMENT IS | | | REQUIRED PRIOR TO PERMIT BEING ISSUED. | | | | | | 2)PROVIDE 2 CURRENT COPIES OF METRO-DADE | | | OR SBCCI PRODUCT APPROVALS FOR ROOF | | | COVERING MATERIALS. | | | | | | 3)THE STRUCTURAL NOTES ON SHEET S-3 #10 | | | AND #11 REFER TO 1994 SOUTH FLORIDA | | | BUILDING CODE. THE CITY OF W.P.B. HAS | | | ADOPTED THE 1997 STANDARD BUILDING CODE | | | AS AMENDED BY PALM BEACH COUNTY. THE | | | ACCEPTED DESIGN CRITERIA IS SECTION 1606 | | | OF THE 97 SBC OR ASCE 7-95. PLEASE | | | CORRECT. | | | | | | 4)PLEASE INDICATE CONNECTORS THAT WILL | | | BE USED TO PROVIDE A CONTINOUS TIE FROM | | | THE ROOF OF THE GAZEBO TO THE ROOF OF | | | THE CUPOLA. | | | | | | 5)STRUCTURE IS LOCATED IN AN "AO" ZONE | | | AN ELEVATION CERTIFICATE IS REQUIRED. |
|