Notes
Date Text
2001-07-22 00:00:00PLUMBING PLAN REVIEW DENIED (SIXTH TIME)
 NOTE ON PLANS,NEW PLANS SUBMITTED.
 (1) DEPT. OF HOTEL BUSINESS REGULATION
 PLAN REVIEW W/COMMENTS REQUIRED, BEFORE
 PLUMBING PLAN REVIEW.CONTACT FOR APPOINT
 MENT 954-958-5520.
 (2) SHT A2.1,A2.M1 MEN & WOMEN REST RM'S
 PREVIOUS COMMENT RE: HANDICAP STALLS
 SEE REVISION: DCA-FLBC,RULE 9B-7.0042,
 FL ADM.CODE, SEC 4.17.3.FIG 30(E).
 CLEAR FLOOR SPACE FOR W/C AND LAVATORY.
 (3) SHT A2.1 EMPLOYEE REST RM, SHOWER
 STALL, COMPLY W/SEC 4.21, ADA SHO.STALL.
 (3)SHT A2.1,A2.M1, COMPLY WITH SEC 4.1.3
 (19)(A).ADA FIXED SEATING IN A RESTURANT
 (4) SHT A1.2 DETAIL ADA (A)(A1).NOT CUR-
 RENT.SEE NOTE 2 ABOVE.
 (5) SHT A10.2 HANDICAP URINAL SEC 4.18.3
 CLEAR FLR SPACE 30"X 48".
 (6) SHT E3.3 LOCATION OF WTR/HTR, TYPE
 IS NOT CLEAR IF THIS IS ELECTRIC OR GAS
 W/H, SHT A2.0 SHOWS ELECTRIC, SHT P1.6
 SHOWS GWH ON A ELECTRIC W/H SCHEDULE?
 (7) SHT M2.1.2.3, CONDENSATE FROM 7-AHU.
 PROVIDE A ISOMETRIC DRAWING OF A COMMON
 COLLECTION SYSTEM TO A DRY WELL OR STORM
 DRAIN, WITH A RELIEF VENT,SEC,804.3,104.
 (8A) SHT P1.5 SEC 104.3 PLANS REQUIRED.
 PROVIDE ISOMETRIC DRAWINGS FOR THE GAS
 PIPING AND SANITARY DWV.
 (8B) SEE ATTACHED GAS PERMIT APPLICATIO
 REQUIRMENTS, ADDRESS EA OF (10) ITEMS,
 FOR PLAN REVIEW.
 (9) SEC 104.3 PROVIDE KITCHEN EQUIPMENT
 PLANS , WITH EQUIPMENT SCHEDULE,LAY OUT.
 (10A)SHT P1.3,SEC 802 ALL INDIRECT WASTE
 TO FLR SINKS,SAFE WASTE NOT ALLOWED.
 (10B) SUSHI BAR, STILL NO VENT SHOWN.
 (11A) SHT P1,4 WATER PIPING ISOMETRIC.
 (MCWC94) SHOW PIPE SIZES, NO MORE THAN 2
 FIXTURES ON 1/2" C/W, NO MORE THAN 4
 FIXTURES ON 1/2" H/W.
 (11B) SHT-P1.4 SHOWS AIR CHAMBERS,
 SHT P1.6 REFERENCES WATER HAMMER ARREST-
 ORS, REMOVE AIR CHAMBERS AND REFERENCE
 THE WATER HAMMER ARRESTORS, AS LISTED.
 (12) SHT P1.5 ISOMETRIC INCORRECTLY
 LABLED,SHOULD BE GREASE WASTE.
 (13A)SHT P1.6 PLBG NOTES #14, DIELECTRIC
 UNIONS, NOT ALLOWED, SEC 608,MATERIALS.
 (13B) FOOD SERVICE NOTE #2-7"TO 11" W/C,
 FL PUBLIC UTILITIES SUPPLIES 12"-14"W/C.
 (14A) SHT P1.7 DETAIL #10 FUNNEL DRAIN,
 FLOOR SINKS FOR ALL INDIRECT WASTE.S-802
 (14B) DETAIL #18 UNIONS IN CEILING, NOT
 PERMITED. NFPA-54 SEC 3.4.2
 (14C) DETAIL #21 ICE MACHINE, CONDENSER
 UNIT & ICE BIN DRAINS,TO BE SEPERATED,
 CROSS CONNECTION OF CONTAMINATED WASTE.
 SEC 804 FOOD HANDLING.
 (14D) DETAIL #22, NO VENT ON WATER HTR.
 (15)SHT P1.3 DISHWASHER DRAIN CONNECT
 I/D TO SANI.SEWER, LOCAL ORD.#2938-96.
 END OF COMMENTSPAUL SCHMITZ