Plan Review Notes
Plan Review Notes For Permit 00100882
Permit Number 00100882
Review Stop B
Sequence Number 2
Notes
Date Text
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE "AO". WILL NEED ELEVATION
 CERTIFICATE.
 2-REVISE SURVEYS AS REQ'D. SEE COMMENTS.
 3-CLARIFY SIZE OF EGRESS WINDOWS AT 2ND
 FLOOR BEDRMS. DESCRIPTION OF WINDOWS,
 WINDOW SIZES CALLED & PRODUCT APPROVAL
 DON'T MATCH. REVISE/CLARIFY AS REQ'D.
 4-MODEL C DOESN'T COMPLY WITH TABLE 600
 OF SBC 1997 WHEN USING THE SLIDING
 GLASS DOORS OPTION.
 9'-8"+4"=10'-0" UP TO 10' IS 20% OP'NG
 5-SOIL TEST REPORT RECOMMENDS FOOTINGS
 TO HAVE 18" EMBEDMENT. REVISE FOOTINGS
 AS REQUIRED OR PROVIDE CALCS AND/OR
 REASON WHY RECOMMENDATIONS ARE NOT
 NECESSARY TO FOLLOW.
 6-SIGNED, SEALED AND DATED SOIL TEST
 REPORT WAS NOT INCLUDED IN THIS PACK.
 PLEASE SUBMIT.
 7-SPECIFY GLASS AREAS TO HAVE SAFETY
 GLASS. EG: KITCHEN WINDOW.
 SECTION 2405.2 SBC 1997.
 8-PROVIDE PRODUCT APPROVAL FOR:
 -HORIZONTAL SLIDERS (IT'S EXPIRED).
 -FIREPLACES UL LISTING AND SPECS.
 -TWO HOUR CONCRETE BLOCK CERTIFICATION
 FROM MANUFACTURER'S ENGINEER STATING
 THAT CONCRETE BLOCK EQUIVALENT
 THICKNESS COMPLIES WITH ASTM C140 FOR
 2 HR FIRE RESISTANCE.
 SECTION 709.3 SBC 1997.
 -WINDOW MULLIONS.
 -NOTE: USE ONLY ONE TYPE OF PRODUCT
 APPROVAL: SBCCI OR DADE COUNTY TO
 AVOID CONFLICTS AND MISMATCH.
 9-REVISE ENERGY CALCULATIONS FOR MODEL D
 THERE ARE 4 BEDROOMS, NOT THREE.
 10-STORM PANELS:
 -PROVIDE COMPLETE INFORMATION FOR
 STORM PANELS UNDER A SEPARATE PERMIT.
 11-SEE COMMENTS ATTACHED AND ON PLANS,
 INCLUDING THOSE BY THE OTHER TRADES.
 12-SPECIFY DRAFSTOPPING AT 2ND FLOOR
 FRAMING PLAN. SEC. 2305.2 SBC 1997.
 SPECIFY MATERIAL AND LOCATION.
 13-TRUSS DRAWINGS:
 -REVISE ENGINEERED TRUSSES: THERE IS
 ONLY ONE MEAN ROOF HEIGHT FOR ENTIRE
 BUILDING. TABLE 1606.2.A SBC 1997.
 -DESIGN CONSIDERATIONS AT BOTTOM OF
 ENGINEERED TRUSSES STATE "WALL HEIGHT"
 SBC REFERS TO MEAN ROOF HEIGHT, NOT
 "WALL HEIGHT". REVISE AS REQUIRED.
 -TRUSS ENGINEER TO HAVE ORIGINAL
 SIGNATURE ON TRUSS LAYOUT.
 CHAPTER 471 FLORIDA STATUTES.
 -ENGINEERED TRUSS DRAWINGS HAVE TWO
 DIFFERENT SIGNATURES. REVISE AS REQ'D.
 BY CHAPTER 471 FLORIDA STATUTES.
 -UPDATE AND SIGN, SEAL AND DATE ALL
 GENERAL TRUSS DRAWINGS.
 NOTE: DON'T USE OLD COPIES WITH THE
 SEAL OF ANOTHER ENGINEER.
 -CLARIFY WHY THERE ARE TWO DIFFERENT
 T12 TRUSSES?.
  
  
 NOTES:
  
 A)PLEASE USE THE 11"X17" SHEETS FOR
 RESUBMITTALS. IT'S EASIER TO HANDLE
 AND FILE.
 B)IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.
 C)THIS PROVISO APPLIES TO PERMIT NUMBERS
 00100886, 00100888, 00100890 AND
 00100894.