| Plan Review Notes For Permit 00100684 |
| Permit Number |
00100684 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | 1)TWO TOILET ROOMS ARE REQD.PER SPC | | | TABLE 407.SEE SPC SEC.407.1.3. FOR | | | ALLOWED DEDUCTIBLE AREAS.BOTH TOILET | | | ROOMS SHALL BE FULLY HANDICAP ACCESSIBLE | | | | | | 2)A DRINKING FOUNTAIN IS REQD.PER TABLE | | | 407 OF SPC.PROVISIONS SHALL BE MADE FOR | | | PEOPLE WHO HAVE TROUBLE BENDING OR | | | STOOPING. | | | | | | 3)FLOORS AND WALLS IN TOILET ROOMS SHALL | | | BE NONABSORBENT TO A HEIGHT OF 4'PER | | | SBC SEC.1204.2. | | | | | | 4)A FLOOR DRAIN IS REQD.IN THE ADD'L. | | | TOILET ROOM PER SPC SEC.409.4.1.1. | | | | | | 5)PLANS REQUIRE CITY PLACE APPROVAL | | | STAMO. | | | | | | 6)SHT.A-5-GRAB BAR ALONGSIDE WATER | | | CLOSET SHALL BE A MIN.OF 42"PER FACBC | | | SEC.4.26 AND FIG.29. | | | | | | 7)SIZE THE WATER RISER AND THE VENT. | | | | | | CALL IF YOU HAVE QUESTIONS. | | | 561-659-8096,EXT.8377. | | | | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|