Plan Review Notes
Plan Review Notes For Permit 00100684
Permit Number 00100684
Review Stop P
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:001)TWO TOILET ROOMS ARE REQD.PER SPC
 TABLE 407.SEE SPC SEC.407.1.3. FOR
 ALLOWED DEDUCTIBLE AREAS.BOTH TOILET
 ROOMS SHALL BE FULLY HANDICAP ACCESSIBLE
  
 2)A DRINKING FOUNTAIN IS REQD.PER TABLE
 407 OF SPC.PROVISIONS SHALL BE MADE FOR
 PEOPLE WHO HAVE TROUBLE BENDING OR
 STOOPING.
  
 3)FLOORS AND WALLS IN TOILET ROOMS SHALL
 BE NONABSORBENT TO A HEIGHT OF 4'PER
 SBC SEC.1204.2.
  
 4)A FLOOR DRAIN IS REQD.IN THE ADD'L.
 TOILET ROOM PER SPC SEC.409.4.1.1.
  
 5)PLANS REQUIRE CITY PLACE APPROVAL
 STAMO.
  
 6)SHT.A-5-GRAB BAR ALONGSIDE WATER
 CLOSET SHALL BE A MIN.OF 42"PER FACBC
 SEC.4.26 AND FIG.29.
  
 7)SIZE THE WATER RISER AND THE VENT.
  
 CALL IF YOU HAVE QUESTIONS.
 561-659-8096,EXT.8377.
  
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.