| 2001-01-08 00:00:00 | FAILED |
| | COMMENTS |
| | C-2 |
| | NO LARGE TREES ARE TO BE PLANTED ON TOP |
| | OF EXIST. 4" WM ALONG ACACIA ROAD |
| | A 5' MINIMUM DISTANCE FROM A LARGE |
| | TREE TO EXISTING PUBLIC UTILITIES |
| | MUST BE MAINTAINED. |
| | CUT ON PUBLIC WM NOT ALLOWED |
| | C.O. MUST BE INSTALLED AT ROW LINE |
| | WHERE SANITARY SEWER WILL BE MADE UNTO |
| | DIXIE.A FDOT ROW PERMIT MAY APPLY. |
| | EXISTING CURB AND SIDEWALK THAT MAY BE D |
| | DAMAGED BY CONSTRUCTION MUST RE REPLACED |
| | WHERE EXIST DRIVEWAY APPROCHES ARE |
| | ELIMINATED THE SIDEWALK MUST BE REDONE |
| | AND RECURBED. |
| | SPECIFY WITH A NOTE THAT WM IN ROW |
| | MUST BE CLASS 52 CEMENT LINED DIP |
| | |
| | METER MUST BE INSTALLED JUST OUTSIDE OF |
| | PROPERTY. AND A VALVE SHOULD BE |
| | ADDED AFTER METER TO SHUT SEPERATE |
| | FIRE AND DOMESTIC SERVICES INCASE ONE |
| | GOES DOWN. |
| | NO POLLUTION CONTROL PLAN |
| | IT MUST SHOWN SILT FENCE AROUND |
| | CONSTRCUTION AREAS ALONG WITH BALES |
| | OF HAY AND IT MUST LIST PERVIOIUS AND |
| | IMPERVIOUS CALCULATIONS WITH 100% TOTAL |
| | SITE LISTED IN S.F. AND ACRES. |
| | NEW STORM CHRGES WILL BE CLACUALTED FROM |
| | THIS TALLY. |
| | (SEE STORM REQUIREMENTS) |
| | AFTER REVISIONS ARE MADE PLEASE |
| | SUBMITT 2 SETS FOR REVIEW TO PUBLIC |
| | UTILITIES ENGINEERING SERVICES DIV |
| | 1000 45TH ST. ATTENTION DEAN LAUDERMILK |
| | 561 659 8040 |
| | (MAKE SURE YOU USE LATEST STD DETAILS |
| | FOR UTILITY THEY MAY BE REQUESTED AT |
| | [email protected] |
| | HAVE A GREAT DAY. |