| Notes |
| Date |
Text |
| 2002-05-03 00:00:00 | CHECKLIST: | | | 1-INFORMATION REQUESTED ON PROVISO DATED | | | 11-29-00 WAS NEVER SUBMITTED FOR | | | REVIEW. | | | 2-SUBMITTAL FOR SITE SPECIFIC PRODUCT | | | APPROVAL FOR ENTRY DOORS ASSEMBLY: | | | A)INFORMATION DOESN'T MATCH BUILDING | | | CODE USED BY ARCHITECT WHO DESIGNED | | | THE BUILDING.(SBC 1997 NOT FBC 2001). | | | B)DESIGN PRESSURES USED DON'T MEET THE | | | DESIGN PRESSURES CALCULATED BY THE | | | ARCHITECT. | | | C)AS PER BLDG OFFICIAL: SITE SPECIFIC | | | INSTALLATIONS REQUIRES PROFESSIONAL OF | | | RECORD TO REVIEW "PRODUCT APPROVAL" | | | ENGINEERING INFORMATION AND CERTIFY | | | (SIGNED AND SEALED) THAT SUCH PRODUCT | | | WILL BE STRUCTURALLY ADEQUATE TO BE | | | INSTALLED IN THE STRUCTURE HE DESIGNED | | | D)WRONG PROJECT ADDRESS. REVISE AS REQ'D | | | NOTE: ENGINEER'S CALCULATIONS SHOW THAT | | | HE CONSIDERS DOOR ASTRAGAL AND DEAD | | | BOLT TO SATISFY HIS CALCULATIONS. | | | NEED TO CHECK THAT THIS LOCKS WILL | | | COMPLY WITH EGRESS REQUIREMENTS TO | | | AVOID CONFLICTS. |
|