| Date |
Text |
| 2001-01-08 00:00:00 | DENIED |
| | |
| | 1)IMPACT FEES MUST BE PAID TO PALM BEACH |
| | COUNTY, PLANS STAMPED BY THEM AND COPY |
| | OF RECEIPT SUBMITTED TO CITY OF W.P.B. |
| | BUILDING DEPT. BEFORE A PERMIT TO |
| | CONSTRUCT WILL BE ISSUED. |
| | |
| | 2)PROVIDE 2 CURRENT COPIES OF METRO-DADE |
| | OR SBCCI PRODUCT APPROVALS FOR EXTERIOR |
| | STEEL DOOR. APPROVAL THAT WAS SUBMITTED |
| | HAD EXPIRED. |
| | |
| | 3)PROVIDE 2 CURRENT COPIES OF METRO-DADE |
| | OR SBCCI PRODUCT APPROVALS FOR ROOFING |
| | MATERIAL AND STORM PANELS. |
| | |
| | 4)MISSLE IMPACT PROTECTION IS REQUIRED |
| | ON ALL EXTERIOR WINDOWS. CITY AMENDMENTS |
| | TO 97 SBC. |
| | |
| | 5)PROVIDE SPACING AND TYPE OF WOOD THAT |
| | WILL BE USED FOR RAFTERS. SPECIFY TYPE |
| | OF CONNECTORS (HURRICANE STRAPS) THAT |
| | WILL BE USED TO ANCHOR RAFTERS TO TIE |
| | BEAM AT NEW AND EXISTING WALLS. |
| | |
| | 6)INDICATE ON PLANS TIE BEAMS, COLUMNS |
| | (FILLED CELLS), LINTELS THAT WILL BE |
| | USED. INCLUDE THE NUMBER AND SIZE OF |
| | REINFORCING STEEL. |
| | |
| | 7)INDICATE ON PLANS HOW NEW WALLS,TIE |
| | BEAMS AND FOUNDATION WILL BE CONNECTED |
| | TO EXISTING. |
| | |
| | 8)INDICATE TYPE OF FURRING THAT WILL BE |
| | USED ON BLOCK WALLS. PROVIDE FIRE BLOCK- |
| | ING WHERE WALLS MEET CEILING. |
| | |
| | 9)IF ADDITION IS TO BE MECHANICALLY |
| | HEATED OR COOLED,PROVIDE ENERGY |
| | CALCULATIONS INCLUDING MANUAL"J" CALCS. |
| | PER 97 FL ENERGY EFFICIENCY CODE. |
| | |
| | 10)INDICATE ON PLANS TYPE AND R VALUE OF |
| | INSULATION FOR WALLS AND CEILINGS. |
| | |
| | 11)PROVIDE ATTIC VENTILATION PER 97 SBC |
| | SEC. 2309.7 |
| | |
| | 12)ASPHALT SHINGLES REQUIRE A MINIMUM |
| | 2:12 PITCH PER 1504.2 97 SBC. INDICATE |
| | ROOF COVERING APPLICABLE TO A FLAT ROOF. |
| | |
| | 13)PROVIDE DETAILS OF WINDOW AND DOOR |
| | BUCK CONNECTIONS. |
| | |
| | 14)PROVIDE FLOOR PLAN OF EXISTING HOUSE |
| | INDICATING LOCATION OF BEDROOMS AND DOOR |
| | & WINDOW OPENINGS AND SIZES. THIS INFO |
| | IS NEEDED TO DETERMINE EGRESS AND |
| | PERCENTAGE OF ALLOWABLE OPENINGS. |