| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: |
| | 1-PROVIDE SOIL TEST REPORT AS PER SECT'N |
| | 1804.2.7.2 AND TABLE 1804.2.7.3 OF |
| | CITY AMENDMENTS TO SBC 1997. |
| | 2-PROVIDE COMPLETE STORM PANELS INFO. |
| | UNDER A SEPARATE PERMIT. |
| | 3-PROVIDE PRODUCT APPROVAL FOR: |
| | -INSWING FRENCH DOOR WITH SIDELITES. |
| | -BBQ UL LISTING AND SPECIFICATIONS. |
| | -OUTSWING FRENCH DOORS. |
| | 4-USE SITE SPECIFIC PRODUCT APPROVAL |
| | FORM ATTACHED FOR INSWING ENTRY DOOR. |
| | |
| | -THIS FORM TO BE SIGNED, SEALED & DATED |
| | BY THE MANUFACTURER'S ENGINEER AND BY |
| | THE ENGINEER OF RECORD. |
| | -PLEASE AVOID UNNECESSARY RETURNS. MAKE |
| | SURE FORM IS FILLED COMPLETELY WITH |
| | ALL THE SPECIFICATIONS AND THE |
| | ENGINEERS NAMES, LICENSE NUMBERS AND |
| | ADDRESSES ARE CLEARLY INCLUDED. |
| | -FILL IN THE JOB SPECIFIC ADDRESS. |
| | 5-PROVIDE CERTIFICAT'N FROM MANUFACTURER |
| | STATING THAT CONCRETE BLOCK EQUIVALENT |
| | THICKNESS WILL PROVIDE TWO HOUR FIRE |
| | RATING ACCORDING TO ASTM C 140. |
| | SECTION 709.3 SBC 1997. |
| | 6-REVISE DOOR BUCK DETAIL. BUCK SIZE IS |
| | 2X4 AND ANCHOR SPECIFIED IS 1 1/2" |
| | LONG. |
| | 7-GARAGE DOOR APPROVED DRAWINGS ARE NOT |
| | LEGIBLE. PLEASE RESUBMIT. |
| | 8-FLOOD ZONE "AO". PROVIDE ELEVATION |
| | CERTIFICATE. |
| | |