Plan Review Notes
Plan Review Notes For Permit 00090113
Permit Number 00090113
Review Stop R
Sequence Number 2
Notes
Date Text
2001-01-08 00:00:00CHECKLIST:
 1-STRUCTURAL DRAWINGS NEED TO BE SIGNED,
 SEALED AND DATED BY THE STRUCTURAL
 ENGINEER OF RECORD.
 -STRUCTURAL DRAWINGS TO BE COORDINATED
 WITH THE ARCHITECTURAL DRAWINGS.
 KEYED DETAILS DON'T MATCH THE ACTUAL
 CONDITIONS. PLEASE REVIEW ALL ARCH'AL
 AND STRUCTURAL DRAWINGS AND PROVIDE
 A CLEAR COMPLETE SET OF CONSTRUCTION
 DOCUMENTS.
 2-REVISE THE DESIGN CERTIFICATION FOR
 WIND LOAD COMPLIANCE FORM. MEAN ROOF
 HEIGHT IS +/- 31'-6" NOT 24'. SEE
 COMMENTS ON THE FORM.
 -ALSO, CLARIFY WHAT IS THE EB6612
 NUMBER FOR. THIS DOESN'T MATCH THE
 ENGINEER LICENSE NUMBER ON THE SEAL.
 3-THERE IS NO INFORMATION GIVEN FOR THE
 SPIRAL STAIRS. SPECIFICATIONS,FOOTING,
 DIMENSIONS, DETAILS, ETC.
 4-PROVIDE CONSTRUCTION DETAILS FOR BAY
 WINDOW AT BREAKFAST AREA. ATTACHMENT
 OF WINDOWS TO THE STEEL COLUMN.
 5-PROVIDE ENGINEERS CERTIFICATION FOR
 SOIL DEMUCKING AND FILLING AS PER
 SOIL TEST REPORT RECOMMENDATIONS.
 6-PROVIDE CALCULATIONS FOR VENTILATION
 OF ATTIC. SEC 2309.7 SBC 1997. VERIFY
 SIZE AND SPACING OF VENTS SPECIFIED.
 7-OWNER/AGENT TO SIGN AND DATE THE
 ENERGY CALCULATIONS.
 8-PROVIDE ATTIC ACCESS AT MASTER BEDROOM
 ROOF WING. SEC 2309.6 SBC 1997.
 9-GARAGE DOORS PRODUCT APPROVAL DON'T
 MEET THE DESIGN PRESSURES CALCULATED
 BY THE STRUCTURAL ENGINEER.
 10-SPECIFY AND IDENTIFY THE SHEARWALLS.
 11-PROVIDE PRODUCT APPROVAL FOR:
 -FRENCH DOORS WITH FIXED GLASS ASSEMBLY
 AS SHOWN ON COVERED PATIO AREA.
 -FLAT ROOF SYSTEM (EXPIRED).
 -SINGLE HUNG WINDOWS AND ROUND WINDOWS.
 -MULLIONS FOR MISSILE IMPACT ASSEMBLIES
 -FIREPLACE UL LISTING & SPECIFICATIONS.
 12-PROVIDE COMPLETE INFORMATION FOR
 STORM PANELS, INCLUDING COMPLETE
 INSTALLATION SCHEDULE (SEE ATTACHED
 SAMPLE) AND KEY PLAN AND CIRCLE THE
 MOUNTING CONDITIONS AND ANCHORS USED.
 NOTE:THIS INFORMATION MAY BE SUBMITTED
 LATER UNDER A SEPARATE PERMIT.
 13-NORANDEX WINDOWS AND DOORS SITE
 SPECIFIC PRODUCT APPROVAL NEED TO BE
 SIGNED,SEALED,DATED BY THE STRUCTURAL
 ENGINEER OF RECORD AS WELL.
 -SPECIFY WINDOWS/DOORS AND COMPONENTS
 TO BE USED IN THIS SITE SPECIFIC
 APPLICATION.
 -ENGINEER TO INCLUDE LEGIBLE NAME,
 ADDRESS, LICENSE NUMBER AS REQUESTED
 BY CHAPTER 471 OF FLORIDA STATUTES.
 14-SEE COMMENTS ON PRODUCT APPROVALS
 SUBMITTED AND ON REVIEWED SET OF
 DRAWINGS.
  
  
  
 NOTES:
 -IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 X 8232.
 -PLEASE RETURN REVIEWED SET AFTER
 CORRECTIONS ARE DONE TO THE ORIGINAL
 DRAWINGS IN ORDER TO EXPEDITE THE
 REVIEW PROCESS.