| 2001-01-08 00:00:00 | CHECKLIST: |
| | 1-PAY IMPACT FEES TO PALM BEACH COUNTY. |
| | BRING STAMPED DRAWINGS AND RECEIPT. |
| | 2-SPECIFY SAFETY GLASS WHERE REQUIRED. |
| | SEE PLANS AND SEC 2405.2 SBC 1997. |
| | 3-PROVIDE ATTIC ACCESS AT MASTER BEDROOM |
| | ROOF WING. SEC 2309.6 SBC 1997. |
| | 4-PROVIDE SURVEY WITH BUILDING LAYOUT. |
| | SURVEY SUBMITTED IS FOR MORTGAGE USE, |
| | NOT FOR BUILDING PERMIT. |
| | 5-PROVIDE SOIL TEST REPORT WITH THE MIN. |
| | INFORMATION REQUIRED ON SEC. 1804.2.7 |
| | AND TABLE 1804.2.7.3 CITY AMENDMENTS. |
| | 6-SPECIFY THE DESIGN PRESSURES AT ALL |
| | EXTERIOR OPENINGS. |
| | NOTE: ALL STRUCTURAL DESIGN SHALL |
| | CONFORM TO SSTD-10-97 WHICH IS THE |
| | PRESCRIPTIVE STANDARD CODE ADOPTED BY |
| | THE CITY OF WEST PALM BEACH WHEN THE |
| | DESIGN IS NOT PERFORMED BY A LICENSED |
| | ARCHITECT OR ENGINEER. SEE SECTION |
| | 104.2.3 OF CITY AMENDMENTS TO SBC 1997 |
| | 7-PROVIDE COMPLETE CONSTRUCTION DETAIL/ |
| | SECTION TRHU BALCONIES. SEC. 104.2.2 |
| | CITY AMENDMENTS TO SBC 1997. |
| | 8-PRODUCT APPROVAL SUBMITTED FOR GARAGE |
| | DOORS REQUIRE SUPPORTING BUCK DETAIL |
| | TO BE DESIGNED BY AND ARCHITECT OR |
| | ENGINEER. SEE SEC 9.3 OF THE PRODUCT |
| | APPROVAL REPORT AND GENERAL NOTE ON |
| | APPROVED DRAWINGS. |
| | 9-MISSING DRAWINGS A-10 & S-3. SEE INDEX |
| | 10-STRUCTURAL PLANS: |
| | -CLEARLY KEY ALL DETAILS THAT APPLY TO |
| | THIS PROJECT. |
| | 11-PROVIDE COMPLETE LOAD CALCULATIONS |
| | (REACTIONS AND UPLIFT) AND PROVIDE A |
| | COMPLETE ANCHOR SCHEDULE. USE SSTD 10- |
| | 97. SEC. 104.2.3 CITY AMENDMENTS. |
| | 12-PROVIDE A COMPLETE CHIMNEY DETAIL/ |
| | SECTION SHOWING ALL FASTENERS AND |
| | STRUCTURAL COMPONENTS. SECTION 104.2.2 |
| | CITY AMENDMENTS. |
| | 13-FOUNDATION, SECOND FLOOR AND ROOF |
| | PLANS NEED MORE INFORMATION: |
| | -PROVIDE COMPLETE FRAMING DETAILS. |
| | -SPECIFY TRUSS GIRDER SUPPORTS AND |
| | CONNECTIONS. |
| | USE SSTD 10-97 AS REFERENCE. |
| | 14-PROVIDE COMPLETE 2 STORY WALL SECTION |
| | SPECIFYING ALL CONNECTORS. |
| | USE SSTD 10-97. |
| | 15-SPECIFY AND IDENTIFY THE SHEARWALLS. |
| | USE SSTD 10-97. |
| | 16-PROVIDE PRODUCT APPROVALS FOR: |
| | -FRENCH DOORS WITH SIDELITES AND FRENCH |
| | DOORS WITHOUT SIDELITES. |
| | -FRENCH DOORS WITH FIXED GLASS ASSEMBLY |
| | AS SHOWN ON COVERED PATIO AREA. |
| | -ROOF TILE AND FLAT ROOF SYSTEM. |
| | -SINGLE HUNG WINDOWS. |
| | -WINDOW AND DOOR MULLIONS. |
| | -BUTT GLAZING ASSEMBLY BY BREAKFAST. |
| | -FIREPLACE LISTING MEETING THE |
| | REQUIREMENTS OF UL 127. |
| | 17-ADDITIONAL PERMIT FEES ARE OWED FOR |
| | LOW PROJECT VALUATION AND RADON FEES: |
| | $681.96. |
| | 18-SEE ADDITIONAL COMMENTS ON PLANS AND |
| | COMMENTS BY THE OTHER TRADES. |
| | |
| | |
| | |
| | |
| | |
| | NOTES: |
| | -PLEASE RETURN REVIEWED SET AFTER THE |
| | CORRECTIONS ARE MADE TO THE ORIGINAL |
| | DRAWINGS IN ORDER TO EXPEDITE THE |
| | REVIEW PROCESS. |
| | -IF YOU HAVE ANY QUESTIONS, PLEASE FEEL |