2001-01-08 00:00:00CHECKLIST:
 1-PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING STAMPED DRAWINGS AND RECEIPT.
 2-PROVIDE SAFETY GLASS AT BREAKFAST
 WINDOW. SEE PLANS. SEC. 2405.2 SBC/97.
 3-EGRESS WINDOWS AT BEDROOM #2 DON'T
 COMPLY WITH SECTION 1005.4.4 SBC 1997.
 -SIZE OF WINDOW SPECIFIED FOR BEDROOM
 #2 IS NOT CLEAR.
 4-STRUCTURAL ENGINEER TO SEE SOIL TEST
 REPORT FOUNDATION RECOMMENDATIONS. IT
 SAYS THAT "EXTERIOR FOUNDATIONS SHOULD
 BEAR AT LEAST 18 INCHES BELOW ADJACENT
 OUTSIDE FINAL GRADES". REVISE FOOTINGS
 SIZE AS RECOMMENDED OR PROVIDE LETTER
 CERTIFYING THAT HE READ THE SOIL TEST
 REPORT AND HIS DESIGN IS ADEQUATE TO
 THE SITE CONDITIONS.
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
 5-PROVIDE SIGNED, SEALED AND DATED SOIL
 TEST REPORT. CHAPTER 471 FL. STATUTES.
 6-PROVIDE ATTIC ACCESS AT GARAGE AREA.
 SECTION 2309.6 SBC 1997.
 7-PROVIDE PRODUCT APPROVALS FOR:
 -SKYLIGHT (EXPIRED)
 -FLAT ROOF SYSTEM.
 -ENTRY DOOR WITH SIDELITE ASSEMBLY AND
 APPROVED DWGS TO BE LEGIBLE & COMPLETE
 -WINDOW MULLIONS
 -ONE HOUR GLASS BLOCK.
 -SLIDING GLASS DOOR WITH TRANSOM ABOVE
 ASSEMBLY.
 8-PROVIDE COMPLETE SECTION AT GABLE END
 WALLS. SPECIFY ALL FASTENERS. SECTION
 104.2.2 CITY AMENDMENTS TO SBC 1997.
 9-TRUSS DRAWINGS:
 -TRUSS ENGINEER TO PROVIDE ORIGINAL
 SIGNATURE AT ALL DOCUMENTS SUBMITTED
 FOR PUBLIC RECORDS. CHAPTER 471 FL. ST
 -TRUSS ENGINEER TO UPDATE ALL GENERAL
 DETAILS AND SIGN, SEAL AND DATE THEM.
 ALSO, MAKE THEM LEGIBLE.
 -TRUSS ENGINEER TO REVISE FLOOR TRUSSES
 BY THE FOYER AREA AS PER INSTRUCTIONS
 OF ENGINEER OF RECORD ON SHEET S-1.
 -ENGINEER OF RECORD TO REVIEW TRUSS
 LAYOUT AND ENGINEERED DRAWINGS PRIOR
 TO SUBMITTAL TO THIS OFFICE.
 *NOTE: SHOP DRAWING REVIEW STAMP NEEDS
 TO SPECIFY WHO OR WHAT FIRM REVIEWED.
 10-PROVIDE BUCK DETAIL FASTENING FOR A
 2X BUCK. PRODUCT APPROVALS FOR DOORS
 AND WINDOWS SUBMITTED CALL FOR
 ATTACHMENT TO 2X BUCKS.
 11-STORM PANELS:
 -INSTALLATION SCHEDULE SUBMITTED IS FOR
 ANOTHER MODEL. ALSO: USE CITY SAMPLE
 ATTACHED AND FILL IN ALL INFORMATION
 CORRECTLY.Y PLAN
 -PROVIDE KEY PLAN.
 12-SEE COMMENTS ON PLANS, INCLUDING
 COMMENTS BY THE OTHER TRADES AND
 REVISE ORIGINALS AS REQUIRED.
  
  
 NOTES:
 -CONTRACTOR TO UPDATE THE LICENSE.
 -RETURN REVIEWED AFTER ALL CORRECTIONS
 ARE DONE TO ORIGINAL DRAWINGS IN ORDER
 TO EXPEDITE THE REVIEW PROCESS.
 -IF YOU HAVE ANY QUESTIONS, PLEASE FEEL
 FREE TO CALL JULIO GOMEZ AT 659-8096
 EXT. 8232.