2001-01-08 00:00:00***************PROVISO******************
 1)PROVIDE PRODUCT APPROVAL FORM FOR
 GARAGE SIDE ENTRY DOOR WITH ORIGINAL
 SIGNATURE,DATE AND EMBOSSED SEAL OF
 ENGINEER CERTIFYING PRODUCT AND DESIGN
 PROFESSIONAL OF RECORD. ALSO,PROVIDE
 JOB SITE LOCATION ON FORM.
  
 2)THE LETTER FROM THE ENGINEER CERTIFY-
 ING THE ENTRY DOOR FOR CODE COMPLIANCE
 MUST BE ACCOMPANIED BY A WET SIGNED,
 DATED AND SEALED LETTER FROM THE DESIGN
 PROFESSIONAL OF RECORD STATING THAT HE
 HAS REVIEWED AND APPROVED THE ENGINEER'S
 REPORT.
  
 3)THE ENGINEERING REPORT FOR THE BUTT
 GLASS ASSEMBLIES INCORRECTLY SITES ASCE
 7-93 AS THE DESIGN CRITERIA USED TO
 DETERMINE THE WIND LOADS. THE ACCEPTED
 DESIGN STANDARDS FOR THE CITY OF WPB ARE
 THE 1997 SBC SEC.1606 OR ASCE 7-95.
 PLEASE CORRECT. ALSO, THE REPORT MUST BE
 WET SIGNED, DATED AND SEALED BY THE
 DESIGNER OF RECORD UPON HIS REVIEW AND
 ACCEPTANCE.