| Plan Review Notes For Permit 00081220 |
| Permit Number |
00081220 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | 1)THE OCCUPANT LOAD SHALL BE BASED ON | | | THE SQ.FOOT AREA OF HABITABLE FLOOR | | | SPACE.SEE SPC SEC.407.1.3 FOR ALLOWED | | | DEDUCTIBLE AREAS.YOU MUST SUBMIT THE | | | SQ.FEET OF THE AREAS,THE SQ.FEET OF EACH | | | AREA BEING DEDUCTED,AND THE FINAL RESULT | | | FOR EACH APPLICABLE OCCUPANCY TYPE. | | | COMPLY W/SPC TABLE 407 FOR MIN.FIXTURE | | | REQS.AS DESIGNED THERE ARE INSUFFICIENT | | | FIXTURES. | | | | | | 2)SHT.A301R-THE DOOR ON THE HANDICAP | | | STALL IN THE MEN'S RESTROOM CANNOT | | | SWING INTO THE CLEAR FLOOR SPACE FOR THE | | | URINAL PER FACBC SEC.4.17.5. | | | | | | 3)A CLEAR FLOOR SPACE MIN.OF 30"WIDE | | | IS REQD.AT THE URINAL PER FACBC SEC. | | | 4.18.3. | | | | | | CALL IF YOU HAVE QUESTIONS. | | | 561-659-8096,EXT.8377. | | | | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|