| Plan Review Notes For Permit 00080910 |
| Permit Number |
00080910 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | DENIED | | | | | | 1)PROVIDE 2 CURRENT COPIES OF METRO-DADE | | | OR SBCCI PRODUCT APPROVALS FOR EXTERIOR | | | WINDOWS THAT WILL BE INSTALLED. | | | | | | 2)PROVIDE PRODUCT APPROVALS FOR ROOFING | | | MATERIALS. | | | | | | 3)PROVIDE NEGATIVE AND POSITIVE DESIGN | | | PRESSURES FOR ADDITION WINDOWS. | | | | | | 4)PROVIDE PRODUCT APPROVALS,KEY PLAN AND | | | INSTALLATION SCHEDULE FOR STORM PANELS | | | OR PRODUCT APPROVALS FOR IMPACT | | | RESISTANT WINDOWS. IMPACT PROTECTION IS | | | REQUIRED FOR ALL EXTERIOR GLAZED | | | OPENINGS.CITY AMENDMENTS SEC.1606.4 | | | | | | 5)PROVIDE ENERGY CODE CALCULATIONS | | | INCLUDING MANUAL "J" PER 97 FL ENERGY | | | EFFICIENCY CODE. | | | | | | 6)WET SIGNATURE OF ARCHITECT IS REQUIRED | | | ON DRAWINGS. SIGNATURE STAMP IS NOT | | | ACCEPTABLE. | | | | | | 7)SAFETY GLASS IS REQUIRED IN BATHROOM | | | PER 97SBC SEC 2405.2. | | | | | | 8)PLEASE INDICATE THE LENGTH OF 5/8" | | | ANCHOR BOLTS @ 24"O.C. ON SHEET S-1. | | | | | | 9)SHEET S-1 SHOWS HELTA 20 TRUSS ANCHORS | | | SHOULD THESE BE HETAL 20? PLEASE RECHECK | | | | | | 10)PLEASE PROVIDE CONNECTION DETAILS OF | | | ADDITION TO EXISTING STRUCTURE FOR WALLS | | | FOOTINGS,AND TIE BEAMS. |
|