Plan Review Notes
Plan Review Notes For Permit 00080584
Permit Number 00080584
Review Stop FIRE
Sequence Number 5
Notes
Date Text
2001-08-22 00:00:001) PLEASE BE ADVISED THAT THIS LOCATION
 IS LOCATED WITHIN THE CITY FIRE LIMITS.
 CERTAIN RESTRICTIONS APPLY.
 2) BALCONY GUARDS AND HANDRAIL TO
 COMPLY WITH THE REQUIREMENTS OF NFPA
 101, THE LIFE SAFETY CODE, 1985 EDITION.
 A) GUARDS MUST BE AT LEAST 42" HIGH
 B) MUST RESIST A 4" SPHERE SINCE THE
 STANDARD BUILDING CODE, 1997 EDITION IS
 MORE RESTRICTIVE THAN THE 1985 EDITION
 OF THE LIFE SAFETY CODE.
 C) MUST BE CONSTRUCTED FOR PRESCRIPTIVE
 REQUIREMENTS OF HORIZONTAL LOADS.
 3) HANDRAILS REQUIRED ON BOTH SIDES OF
 STAIR.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910