| Plan Review Notes For Permit 00080391 |
| Permit Number |
00080391 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | 1)HANDICAP ACCESSIBLE TOILET ROOMS/REST- | | | ROOMS SHALL BE INDELIBY POSTED FOR THE | | | INTENDED USE,BE ON AN ACCESSIBLE ROUTE | | | AND BE AVAILABLE TO PATRONS WITHOUT | | | RESTRICTION DURING NORMAL OPERATING | | | HOURS.THE ACCESSIBLE ROUTE SHALL BE | | | SHOWN ON THE PLANS.FACBC SECS.4.1,4.2, | | | 4.3.,SPC 407.2.2. | | | | | | 2)CONDENSATE DRAIN SHALL CONNECT TO THE | | | COMMON SYSTEM,NOT TO THE LAV.DRAIN. | | | SMC SEC.304.8.3. | | | | | | 3)SUBMIT WATER RISER DIAGRAM FOR REVIEW. | | | COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1 | | | | | | 4)TANKLESS WATER HEATER SHALL BE NOT | | | INFRINGE ON THE REQUIRED CLEAR FLOOR | | | SPACE AND KNEE AND TOE CLEARANCES PER | | | FACBC SECS.4.19.2,4.19.3,FIG.#31,32. |
|