2001-01-08 00:00:001)HANDICAP ACCESSIBLE TOILET ROOMS/REST-
 ROOMS SHALL BE INDELIBY POSTED FOR THE
 INTENDED USE,BE ON AN ACCESSIBLE ROUTE
 AND BE AVAILABLE TO PATRONS WITHOUT
 RESTRICTION DURING NORMAL OPERATING
 HOURS.THE ACCESSIBLE ROUTE SHALL BE
 SHOWN ON THE PLANS.FACBC SECS.4.1,4.2,
 4.3.,SPC 407.2.2.
  
 2)CONDENSATE DRAIN SHALL CONNECT TO THE
 COMMON SYSTEM,NOT TO THE LAV.DRAIN.
 SMC SEC.304.8.3.
  
 3)SUBMIT WATER RISER DIAGRAM FOR REVIEW.
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1
  
 4)TANKLESS WATER HEATER SHALL BE NOT
 INFRINGE ON THE REQUIRED CLEAR FLOOR
 SPACE AND KNEE AND TOE CLEARANCES PER
 FACBC SECS.4.19.2,4.19.3,FIG.#31,32.