2001-01-08 00:00:00CHECKLIST:
 1-PAY IMPACT FEES. TAKE DRAWINGS TO THE
 PALM BEACH COUNTY BUILDING (AUSTRALIAN
 AND SOUTHERN BLVD). THEY WILL STAMP
 DRAWINGS AND WILL GIVE YOU A RECEIPT.
 2-PROPOSED ADDITION WILL BE NEXT TO AN
 EXISTING METAL BUILDING. SHOW HOW
 COMPLYING WITH TABLE 600 OF SBC 1997
 FOR FIRE RATING AND PERCENTAGE OF
 OPENINGS ALLOWED.
 -PROVIDE ALL DIMENSIONS IN SITE PLAN:
 DISTANCE BETWEEN BUILDINGS AND REAR
 PROPERTY LINE.
 3-PROVIDE ATTIC ACCESS.SEC 2309.6 SBC/97
 4-PROVIDE SPECIFICATIONS FOR ATTACHEMENT
 OF PLYWOOD ROOF SHEATHING AND T-1-11
 EXTERIOR WALL COVERING. SECTION 2306
 CITY AMENDMENTS.
 5-SPECIFY SIZE OF EXISTING FOOTING.
 NOTE: FOOTING TO BE MINIMUM 12" BELOW
 GRADE AND 4" ABOVE GRADE AS PER SECT'N
 1804.1.9 CITY AMENDMENTS AND SECTION
 1804.1.3 SBC 1997.
 6-SPECIFY CALCULATED DESIGN PRESSURES AT
 ALL EXTERIOR OPENINGS. SEC 1606 SBC/97
 7-WALL SECTION:
 -PROVIDE 1 1/2" WATER STOP. SECTION
 2111.6 CITY AMENDMENTS.
 8-PROVIDE COMPLETE DETAIL AND SPECS FOR
 CONSTRUCTION OF GABLE END. SECTION
 104.2.2 CITY AMENDMENTS.
 9-PROVIDE THE FOLLOWING INFORMATION:
 -ROOF PITCH.
 -WINDOW SIZES
 SECTION 104.2.2 CITY AMENDMENTS.
 10-ENERGY CALCULATIONS:
 -FILL COMPLETELY, INCLUDING PAGE TWO.
 -ARCHITECT TO SIGN, SEAL AND DATE FORM
 AS REQUIRED BY CHAPTER 481 FL. ST.
 11-BEDROOM AND BATHROOM TO COMPLY WITH
 THE MINIMUM REQUIREMENTS FOR LIGHT AND
 VENTILATION. SEE SECTIONS 1203.1.2,
 12031.4 AND SECTION 1203.4.2 SBC 1997.
 12-SPECIFY CEILING HEIGHTS. SECTION
 1203.2 SBC 1997.
 13-CLARIFY IF RE-ROOFING ENTIRE HOUSE.
 SEE WALL SECTION.
 14-PROVIDE HOW ARE OPENINGS FRAMED TO
 RECEIVE STORM PANELS.SEC 104.2.2 CITY
 AMENDMENTS.
 15-PRODUCT APPROVALS:
 -STORM PANELS:
 *PROVIDE A KEY PLAN AND A COMPLETE
 INSTALLATION SCHEDULE. SEE ATTACHED.
 *DRAWINGS NEED TO BE SIGNED AND SEALED
 TO BE VALID FOR PERMIT. SEE NOTE #10
 OF GENERAL NOTES. PAGE 1 OF 5.
 -EXTERIOR DOOR PRODUCT APPROVAL IS
 EXPIRED.
 -SINGLE HUNG PRODUCT APPROVAL DRAWINGS
 ARE NOT LEGIBLE.
 16-CONSTRUCTION VALUE DECLARED IS TOO
 LOW. VALUE WILL BE RE-ADJUSTED GIVING
 A MORE REALISTIC NUMBER.
  
  
 NOTES:
 -CONSTRUCTION VALUE DECLARED IS TOO LOW.
 CONSTRUCTION VALUE WILL BE ADJUSTED
 WITH A MORE REALISTIC NUMBER. OWNER
 WILL NEED TO RECORD A NOTICE OF
 COMMENCEMENT.
 -IF YOU HAVE ANY QUESTIONS, PLEASE FEEL
 FREE TO CALL JULIO GOMEZ AT 659-8096
 EXT. 8232.