| Date |
Text |
| 2001-01-08 00:00:00 | UPON REVIEWING THE ABOVE REFERENCED |
| | PROJECT THE FOLLOWING ITEMS WILL NEED |
| | TO BE ADDRESSED: |
| | |
| | SHEET C2 CALLS OUT REMOVING DRIVEWAY |
| | ENTRANCES THAT ARE NOT NEEDED, PLACE |
| | A NOTE THAT CONTRACTOR SHALL REPLACE |
| | DRIVEWAYS TO BE REMOVED WITH NEW SIDE- |
| | WALK AND CURB TO MATCH EXISTING (TYP) |
| | |
| | SHEET C3.00 |
| | A POLLUTION PREVENTION PLAN MUST BE |
| | PROVIDED SHOWING A SILT FENCE AROUND |
| | THE ENTIRE SITE AND A SILT FENCE INSTALL |
| | ATION DETAIL.THIS PLAN MUST CONTAIN |
| | THE SITE INFORMATION AS SHOWN ON SHEET |
| | C-1.00. YOU MAY COMBINE THE SITE PLAN |
| | AND POLLUTION CONTROL PLAN TOGETHER. |
| | (SITE PLAN AND POLLUTION CONTROL PLAN) |
| | |
| | SHEET C-4.00 |
| | A CLEAN-OUT IS REQUIRED AT THE POINT OF |
| | SEWER ENTERING THE BUILDING AND AT THE |
| | BACK OF SIDEWALK. CONTRACTOR SHALL |
| | VERIFY THE CLEAN-OUT IS IN PLACE OR |
| | CUT ONE INTO EXISTING SEWER SERVICE. |
| | |
| | SHEET C-4.00 |
| | THE CITY OF WEST PALM BEACH DOES NOT |
| | ALLOW 3" FIRELINES.IT MUST BE A 2" |
| | WITH A 2" VALVE. THE OTHER OPTION WOULD |
| | BE TO RUN A NEW 8" WM ALONG HAMPTON OFF |
| | DIXIE HWY. TO THEN SERVE THIS BUILDING |
| | WITH A 4" FIRELINE. |
| | |
| | SHEET C-4.00 |
| | A VALVE MUST BE PROVIDED TO SEPERATE |
| | PRIVATE FIRE LINE AND WATER SERVICE LINE |
| | SO THAT WHEN ONE IS DOWN FOR SERVICE |
| | THE OTHER WOULD BE IN OPERATION. |
| | |
| | SHEET C-4.00 |
| | PLACE METER IN SIDEWALK WITH LOCKING LID |
| | AND TOUCHREAD OPTION. |
| | |
| | GENERAL COMMENT: |
| | PLEASE LABEL PROPERTY LINE OR SHOWN IN A |
| | DIFFERENT LINE TYPE. |
| | |
| | IN STANDARD DETAIL SHEET PLEASE |
| | PROVIDE THE FOLLOWING: |
| | CWPB TYPICAL TRENCH DETAIL OR PAVEMENT |
| | REPLACEMENT DETAIL. |
| | |
| | GENERAL NOTES: |
| | 1.A SEPARATE IRRIGATION METER IS |
| | SUGGESTED TO SAVE ON THE MONTHLY |
| | WATER BILL. AN APPROVED BACKFLOW |
| | PREVENTER WILL NEED TO BE INSTALLED |
| | ON THIS LINE. |
| | |
| | 2.NO WATER AND OR SANITARY LINES CAN BE |
| | LAID, IF PLANS ARE NOT SUBMITTED TO US, |
| | SEPARATELY AND PRIOR TO SUBMITTAL FOR A |
| | BUILDING PERMIT FROM BUILDING AND ZONING |
| | ANDSERVICE WILL NOT BE GRANTED. |
| | SUBMITT TO MANNY GONZALEZ |
| | PUBLIC UTILITIES PROJECT SPECIALIST |
| | 1000 45TH STREET |
| | WEST PALM BEACH, FL 33415 |
| | (561) 659-8040 EXT. 2306 |
| | (2 SETS MINIMUM) |
| | |
| | 3.ALL BROKEN SIDEWALKS ALONG THE PROPERT |
| | Y MUST BE REPLACED. |
| | |
| | 4.ALL DRIVEWAYS THAT WILL NOT BE USED MU |
| | ST REMOVED AND THE REGULAR CURBS |
| | (&GUTTERS)MUST BE REPLACED. |
| | |
| | 5.ALL BROKEN UP CURBS (& GUTTERS) |
| | MUST BE REPLACED. |
| | |
| | 6.ALL DRIVEWAY APPROACHES MUST BE (AT A |
| | MINIMUM) PER CITY STANDARD DETAIL INDEX. |
| | |
| | 7.ALL GRADES FOR CITY SIDEWALKS WILL BE |
| | SET BY THE CITY SURVEY CREW, CALL 659-80 |
| | 40ASK FOR ED RYAN TO SET UP AN |
| | APPOINTMENT. |
| | |
| | 8. NO DUMPSTER IS SHOWN. THIS SITE WILL |
| | NOT GENERATE TRASH>???? |
| | |
| | POLLUTION PREVENTION PLAN MUST BE KEPT |
| | ON SITE AT ALL TIMES DURING CONSTRUCTION |
| | THE PLAN SHALL BE INSTALLED IN THE FIELD |
| | PRIOR TO ANY EARTHWORK. |