2001-01-08 00:00:00PLUMBING PLAN REVIEW
 (1) SHT P2.1 DISHWASHER #63, DISPOSAL
 #68,RUN TO SANITARY SEWER, LOCAL
 ORDINANCE REGIONAL SEWER TREATMENT PLANT
 (2) SHT P0.1 ICE MACHINE #22, SEPERATE
 DRAINS ON ICE BIN & CONDENSER UNIT.
 BACKFLOW ORDINANCE #2853-95.
 (3) SHT P1.1 GREASE WASTE ,COMMON SYSTEM
 PROVIDED BY OWNER.
 (4) SHTP5.1 GREASE WASTE ISOMETRIC,
 ALL INDIRECT WASTE TO FLOOR SINKS.
 SPC 94 SEC 807.
 (5) SHT P6.1 GAS ISOMETRIC, ADD UNION
 DOWN STREAM OF MANUAL SHUT OFF.
 NFPA 54 SEC 5.5.4