Plan Review Notes
Plan Review Notes For Permit 00070350
Permit Number 00070350
Review Stop B
Sequence Number 2
Notes
Date Text
2001-01-08 00:00:00 
  
  
  
  
 1. PROVIDE SIGNED AND SEALED FLORIDA
 ENERGY SHEETS, 1997 EDITION
 2. FIRE SPRINKLER PERMIT REQUIRED PRIOR
 TO ISSURANCE OF BUILDING PERMIT.
 3. EXTERIOR SIGNS REQUIRE SEPRATE PERMIT
 4. SUBMIT APPROVAL FROM SPECIAL
 INSPECTOR.
 5. EXTERIOR GLAZING: PROVIDE PRODUCT
 APPROVAL SHEETS, METRO DADE COUNTY
 OR SBC 1997 SSTD 12-97
 6. ALL WOOD FRAMING TO BE FIRE RETARDANT
 LUMBER AS PER SBC 1997 CHAPTERS 6&7
 7. HANDICAP FITTING ROOM: DOOR SHALL NOT
 SWING INTO TURNING RADIUS, FLORIDA
 ADA SECTION 4.35.2
 8. PAGE 1: PROJECT DATA CODE REQUIREMENT
 REVISE NEC 1996 TO NEC 1999.
 9. TENTANT SEPERATION TO MEET SBC 1997
 TABLE 704.1 OCCUPANCY SEPERATION
 REQUIREMENTS.( BOTH SIDES MUST BE
 COMPLETED PRIOR TO C.O.)
 10. SHUTTERS ARE INDICATED ON DETAIL14
 SHEET 7, PROVIDE PRODUCT APPROVAL
 INFORMATION SHEETS,INDICATE AREA OF
 STORAGE, SHOULD SHUTTERS BE STORED ON
 END SHUTTERS SHALL BE DESIGNED FOR
 ADDITIONAL LOADING; PROVIDE LETTER
 FROM TENTANT AS WHO WILL INSTALL AND
 TIME NEED TO INSTALL FOR APPROVAL OF
 BUILDING OFFICAL.